  1. bazdaman

    Are all TRVs made equal? Are Wolseley any good?

    The plumb center trade fix are myson contract body's. The plumb center heads look better. I believe they are made by myson. I like them and fit them regularly, also come in trv and lockshield pack now
  2. bazdaman

    Ideal Response 80 recommisioning problem.

    Good to hear it's Working. Its always nice to get an update
  3. bazdaman

    Ideal Response 80 recommisioning problem.

    If you have an ideal response chances are it won't last long, not seen one for years, they became obsolete very quickly. A decent cycle pump with gauge will do the job. Just make sure heating side has a drain off open when you pump the vessel up.
  4. bazdaman

    Gas Safe Engineer

    My BIL has done just that at a total cost of approx 3k
  5. bazdaman

    Baci Solo 3 PFL 50 Worth Repairing?

    They was a good boiler worth repairing, recently the spares prices have shot up rendering a lot of repairs BER unfortunately
  6. bazdaman

    Baxi Combi 105HE Central Heating Problem

    That's not the boiler he is talking about, that is an instant
  7. bazdaman

    Baxi Combi 105HE Central Heating Problem

    The rear most on top is not a CH micro switch, it proves the pump is running and has to prove on HW and CH
  8. bazdaman

    Leaking stopcock...Water main cover removal....

    Jam a driver in to prise it open
  9. bazdaman

    Removing radiator

    Don't link together just cap each end individually
  10. bazdaman

    Valiant ecotec pro28

    Is there a radiator symbol on the boiler display when the stat is calling for heat? It's likely the reciever is not sending power back to the boiler, you can check s codes to confirm or use a multimeter on reciever
  11. bazdaman

    Potterton e133 code after PRV and expansion vessel changed

    An e133 fault has nothing to do whatsoever with an expansion vessel/prv problem. I have never seen a wet pcb cause an e133 fault either.
  12. bazdaman

    Baxi Duo Tec HE 40 heating issue

    I have swapped a pcb for this fault
  13. bazdaman

    Intermittent hot water fault (n)

    Change the hydraulic venturi and diaphragm both parts for under 20 quid. Does the hot water tap light go on and off on shower demand?
  14. bazdaman

    Baxi gas combo boiler 105he

    Good luck returning a pcb!
  15. bazdaman

    Intermittent Baxi combi fault

    Primary thermistor issue I would say
  16. bazdaman

    Adding inhibitor to a towel rail

    Whilst pressurising the vessel, wait for system gauge to read 0bar.
  17. bazdaman

    Valiant eco tech condensate flexi pipe leak

    I would add that to change it, it's easier with the burner section removed so a new seal kit would be needed aswell even so 250 is expensive if that's all he's doin.
  18. bazdaman

    Baxi 80e Pump leak

    You guys must be unlucky, I swap the o rings regularly on these for a drip in that location, 2 screws and thats it. There is actually 3 or 4 o rings (dependant on age) as the connection from block is on a barrel nipple that pulls out.