  1. A

    Replacing Drayton RTS1 with Honeywell DT90E - Wiring change.

    Hi I am about to do the exact same thing...what were the steps with regards to the Neutral connection from the timer, or can we just ignore it and make it safe? Thanks Akbar
  2. A

    Ariston condensing system boilder CH pump overrun

    Hi I have a Ariston microGenus 27 system boiler (condensing) Separate Room stat (simple drayton analogue) Seperate timer. This is a new issue I have not seen before 1. CH and HW set for morning, room temp on stat set at 23c 2. Boiler runs fine for 30mins 3. CH pump overrrun keeps...
  3. A

    Ariston Genus HE 24 Combi - DHW pump overrun issue

    Thanks Tony, so do you provide services within the Berks area if so do you have contact information so I could discuss a possible quote? Thanks Akbar
  4. A

    Ariston Genus HE 24 Combi - DHW pump overrun issue

    Done some further testing last night. So the issue is only there when I demand hot water at full speed, if I open the shower or basin tap mixer to full the flame light LED notification shows its running at full and it do this "30-40 sec cycle with pump overrun" However if I run the...
  5. A

    Ariston Genus HE 24 Combi - DHW pump overrun issue

    well the water is fairly hard where I live so I can expect scale build up. Is this an easy job then? Thanks Akbar
  6. A

    Ariston Genus HE 24 Combi - DHW pump overrun issue

    Was installed by CORGI installer from local area who is very reputable. I intend to call him back anyhow but would like to know the area at possible fault at least. As I spoke to some other heating experts they all mentioned this secondary heater exchanger likely to be blocked, what is the...
  7. A

    Ariston Genus HE 24 Combi - DHW pump overrun issue

    As above Ariston Genus HE 24 - CH works all fine. DHW - set to 50 degrees. Run shower at full pace - will run fine for first few mins then... the DHW pump overrun kicks in every min or so resulting in a few seconds of a colder shower (like a constant cycle of boiler firing on and off)...
  8. A

    WC in garage conversion

    thanks, yes ive heard of those. I look into that straight away.
  9. A

    WC in garage conversion

    Do i require a soil pipe vent of some sort if installing a WC in the garage to a main soill junction to the house (2 inlets, 1 oulet) the garage is circa 15 m away. the drop would be about 1:40 ratio. TIA
  10. A

    Triton Dover Manual Mixer Shower HW/CW wrong way around

    just purchased this from http://www.screwfix.com/prods/89417/Bathrooms/Showers/Mixer-Showers/Manual-Showers/Triton-Dover-Manual-Mixer-Shower and all pipework has been done behind tiling. Just realised the hot and cold water feed are the wrong way around, now I realise this poses a safety...
  11. A

    WC, Sink and Shower drainage from Annex behind house

    Warm Hello to everyone, I am a newbie just looking for some general advice. I have had an annex built at the rear of my house with a WC, Shower and sink waste connections all connected in the following configuration. (please excuse use of terms and correct as necessary) 1. Main brown soil...