  1. K

    Hive overheating hot water.

    Are you sure the immersion hasn't been left on? Does the boiler and pump switch off if you turn the cyl stat down with the boiler running?
  2. K

    Central heating installation HELP!

    Looks ok to me, but choose one rad to act as a bypass by fitting lockshield valves to both ends, and leave them open, this is usually the rasd nearest room stat.
  3. K

    Worcester Greenstar 24i problems

    The blue light tells you that you have power to the boiler, unless it is flashing, which indicates a fault. My first port of call would be to see if the boiler actally has a demand for heat from the stat. If HW is working, then that's quite likely the problem
  4. K

    1 cm thick limescale in toilet

    It would be far easier just to change the pan.
  5. K

    Worcester Bosch Greenstar CDI Conventional - EA error message

    Could be a number of things, but I would need to be in front of the boiler to see what is happening. My bet is flame sensor, but you'll need a GS bod to install it.
  6. K

    Changing both rad valves

    I close the flow/return valves on the boiler which preserves the pressurised water in the exp vessel, and prevents air being drawn into the auto air vent. You just need to depressurise the system via a drain and crack on. If you have a enough play in the pipes, it's easiest to undo one side and...
  7. K

    Condensation inside Gas Condensing Boiler

    Hideous boiler, skip it.
  8. K

    When would you use a boiler bracket?

    Had to do that a number of times where the p/board is thin stuff, or the boiler bracket needs to go where an old balanced flue hole was, and I couldn't core drill the new brick/block.
  9. K

    Ideal standard classic boiler not working

    I've just had to order one of those, 5 day wait.
  10. K

    Boiler replaced not turning off after CH demand from nest has ceased

    Sounds like you have a sticking end switch in one of your zone valves
  11. K

    turned the wrong valve on ideal logic 35 combi boiler

    The black lever next to the pressure gauge will be the flow isolating valve, it should point vertically, not horizontally.
  12. K

    Orange flame gas hob

    Do either of you use a Nebuliser? They will cause odd coloured flames.
  13. K

    Ideal standard classic boiler not working

    If the boiler is firing, where is the heat going? Or is the boiler firing for a very short time? Maybe have a look at the pump, or check for a blockage in the pipework near the pump, where the cold feed from header tank enters the system.
  14. K

    Question regarding LPG quantity and usage...

    Gross weight 105kg??? That would suggest the tare (empty weight) of the bottle is 58kgs. 20 something would be nearer the mark.
  15. K

    Domicompact F24B Ferroli Boiler- F37 error

    As above, then start saving for a replacement boiler:ROFLMAO:
  16. K

    Repairing small hole in condensate pipe?

    Get a coupler of the correct size 21.5mm, cut it in half lengthways, and glue it on the hole.
  17. K

    Can I fit a plume management kit on the flue myself?

    It's a 10min job, pull nose out of flue, drill hole for PMK, fit PMK go home.
  18. K

    Unusual repressurisation system? can't find right valve

    None of those valves will repressure your boiler, look for a silver braided hose somewhere else, maybe further down the pipework?
  19. K

    Magnetic Filters

    I always fit the Magnaclean pro. Easy to clean, & useful for dosing with inhibitor.