Search results

  1. Cisse062410

    Potterton 28 no hot water

    Just an update. I have removed the diverter valve, stripped it down and refurbed it with a kit purchased of eBay as it was seized. It took just over an hour all together. Thanks for all the guidance it's much appreciated.
  2. Cisse062410

    Potterton 28 no hot water

    Ok thanks for the quick response. So the diverter valve is the fault as well as the differential valve diaphragm (which I've already replaced).
  3. Cisse062410

    Potterton 28 no hot water

    The central heating pipes do get hot when turning hot water tap on with boiler set to HW only........ im guessing diverter valve knackered although the pin is rising on the diverter valve.......could that mean the PHEX is blocked?
  4. Cisse062410

    Potterton 28 no hot water

    It just says performa 28 on the label.
  5. Cisse062410

    Potterton 28 no hot water

    It's a performa 28. I have replaced the differential valve diaphragm this morning and the boiler is now firing up correctly, the diverter valve is actuating and pin activating the microswitch but outlet is cold......
  6. Cisse062410

    Potterton 28 no hot water

    After referring back to the manual I have found that I made an error during diagnosis on the first step...... neon illuminated wasn't referring to the dhw neon...... I should stick to fixing robots and welding equipment.....
  7. Cisse062410

    Potterton 28 no hot water

    Its my parents boiler.
  8. Cisse062410

    Potterton 28 no hot water

    Hi I have an issue with a potterton 28 boiler where the hot water system is not working(turn taps on and water stays cold). There are no warning/error lights on and the hot water light doesn't come either. I have done the electrical test as described in the manual and it points to the pcb but I...