Search results

  1. J

    Hive Installation Into Veissman Vitoden 100

    Move the black wire that is currently in 2 to 1
  2. J

    Solving digital thermostat problem

    L1 is the switched live there should be no connection to N1 in your situation. So Red to 4 Blue to 3 Yellow to 1 Nothing to 2
  3. J

    Understanding Low Limit Pipe Stat Wiring

    Common and 1 BREAK on rise. Common and 2 MAKE on rise. So to do what you want connect to common and 2. But I don't think that is a good way of doing it. What controls have you got to stop it getting too hot? The valve should be controlled by a cylinder thermostat that will close it when it...
  4. J

    Dual channel Hive and Drayton Tempus 7 wiring

    Yes it will go straight onto that backplate. Depending on what system you have you might not need a connection to HW off and you will almost certainly not need a connection to CH off. If you have 2 valves (S plan) then it is fine as it is. If you only have 1 valve (Y plan) then you probably...
  5. J

    Hive Multi Zone install on Logic Combi ESP35 boiler

    @ericmark The grey is common, orange is NO. And why are you obsessively going on about opentherm? The OP never mentioned that. To the OP your diagram is mostly right. Don't alter the wiring going to the orange valve wires. Disconnect the 2 black wires going to the brown wires of the valves...
  6. J

    Hive Multi Zone install on Logic Combi ESP35 boiler

    They are motorised valves not pumps. It's up to you how you do it, as you say it would be easy to put the receivers where the existing thermostats are now and wire them as you said. Or you could put them where the valves are and wire them into the wiring box there. If you want to do that I can...
  7. J

    Help! Hive Installation - Worcester Bosch greenstar heatslave ii 18/25

    Yes leave the link form L to HW. No if using a single channel there is no connection to hot water. Boiler - Hive N - N L - L Link L - 1 on the receiver CH to 3
  8. J

    Help! Hive Installation - Worcester Bosch greenstar heatslave ii 18/25

    Yes if your fitting the dual channel Hive. Or only the one between L and CH if your fitting the single channel one.
  9. J

    Potterton EP3000 to Hive wiring help

    N-N L-L 1-1 3-3 4-4 The brown wire that is in 5 to L Then as you say the two wires in C in a connector and the two wires in D on another connector.
  10. J

    Vaillant Ecotec plus 630 no heating hot water

    Yes I meant 24v (as I said in my first post) not 12v.
  11. J

    Vaillant Ecotec plus 630 no heating hot water

    Yes if 230 volt switching is used then the 12 volt link needs removing.
  12. J

    Vaillant Ecotec plus 630 no heating hot water

    Yes remove that link. The boiler will just run constantly with it in place.
  13. J

    Holiday mode

    ALL THREE!!!
  14. J

    Holiday mode

    When in holiday mode the CM907 sets the temperature to 10° by default so no there won't be any freezing!
  15. J

    Holiday mode

    Already given by me. All 3.
  16. J

    Holiday mode

    Yes all 3
  17. J

    Vaillant Ecotec plus 630 no heating hot water

    Has the RT 24v link been removed on the circuit board in the boiler?
  18. J

    Actuator Head

    No it won't.
Back
Top