  1. Combicert

    Stronger fixing Plywood of PSE timber?

    I use ply as mdf tends to go bad quicker when exposed to moisture - i find... but i dare say others may have a different opinion. Never had any problems with ply.
  2. Combicert

    One cold radiator

    Awesome stuff - well done. Glad to have helped.
  3. Combicert

    One cold radiator

    As above really... turn off all rads - then if heat reaches the dodgy rad just turn lockshields on about 1/8th of a turn on other rads... Google/you tube ‘balancing radiators’ - follow their guidance.
  4. Combicert

    Glowworm 18HXI water trap leak and black grit

    When the heat exchanger is first made it’s done so using a process involving sand... this grit can be sand particles left over from the manufacturing process ... or just build up of flecks of byproducts from years of use - as above; condensate is slightly acidic too. Either way, Perfectly...
  5. Combicert

    Expert advice needed on Valliant combi boiler

    Six of one and half a dozen... Yup - I take your point. Whenever i install its just something I do. Force of habit and a result of doing these worcester courses i reckon. I only ever really do worcesters on installs to be honest... i don’t mind doing ideal/baxi et al - but i guess it’s...
  6. Combicert

    ❄️!! Help Worcester ❄️24i RSF-L combi ❄️not working !! ❄️

    Flow pressure switch fault...? Needing masses of flow to get the thing to fire up on hw..? On something that old a call to worcester is the correct call probably...
  7. Combicert

    BG condemn and disconnect boiler - advice appreciated (Thorn Apollo 15/30B)

    Seal gone. Part not immediately available Spilling POC. Correct call by british gas, them’s the regs. If i had to wait a few days for a part to arrive in this instance you’d have to cap it... Shame they ‘cocked up’ - you do wonder about installer incentives though.
  8. Combicert

    Atag A325 drenching in condensate when cold

    Vertex flue? Yeah - engineer not correct in my mind. Post above is quite correct. Check condensate is draining if it is then a flue integrity check would be next stop.
  9. Combicert

    Expert advice needed on Valliant combi boiler

    In this instance Feel free to shoot me down guys. Worcester bosch training used a general rule of thumb of 1.5kw per rad plus 10% for fittings for heating side (not set in stone - but to help with calcs..) Assuming correct incoming pressure boilers should be sized on hw output. I have a...