    HW/CH Noise

    Some boilers have an in built timer on the pcb that starts the pump up for a short period every 24 hours to make sure it doesnt stick They also have an in built frost that that would kick in if temp drps below 5 degrees but still too warm for that and you would feel heat in the pipes
  2. G

    Obsolete gas valve

    this place is saying they have a new one . https://www.gmsspares.com/product/gas-valves-s1008/ideal-gas-valve-rc3-8-sit-0680-009-i0004050/I0004050 Although it says ideal it is a Sit gas valve
  3. G

    Obsolete gas valve

    https://www.ebay.co.uk/itm/365939217583?var=0&mkevt=1&mkcid=1&mkrid=710-53481-19255-0&campid=5338749401&toolid=20006&_ul=GB&customid=CjwKCAjw04HIBhB8EiwA8jGNbc894rLgUUgxI2nY3Xeq3jjf630qCyxaPNX39s4m2PUz-b6hm0pwQBoCCfYQAvD_BwE|0AAAAADihhqV6RFPf7TWB26VKuMQCX-opR|CkwKCAjwsPzHBhAfEjwA_SWgPv2KtS91Bq0cv...
  4. G

    Obsolete gas valve

    https://www.ebay.co.uk/itm/336178554929?chn=ps&_ul=GB&norover=1&mkevt=1&mkrid=710-134428-41853-0&mkcid=2&mkscid=101&itemid=336178554929&targetid=2361039923645&device=c&mktype=pla&googleloc=9046196&poi=&campaignid=21697381820&mkgroupid=170109506289&rlsatarget=pla-2361039923645&abcId=10027101&merch...
  5. G

    How to unscrew this kind of tap?

    get someone to hold the tap
  6. G

    If not a gas leak, why the smell of sulphur "rotten eggs" in kitchen?

    People can smell certain stuff differently . Just because you have turned gas off doesnt mean there is not a leak before the valve It is completely free to call out the emergency service and they certainly do not mind false alarms so give them a call to rule out it being a gas leak 0800 111 999
  7. G

    New boiler

    Potterton 85 he So a powermax ? Not the greatest of boilers and a lot of people will not work on them when they brakdown
  8. G

    Rads - your rules of thumb

    if your looking at stelrad then have a look at wickes radiators these are made by stelrad and far cheaper
  9. G

    What do you think? New boiler required

    lost count of the amount of jobs i have fixed for less money than someone who couldnt fix it and walked away .
  10. G

    What do you think? New boiler required

    Totally agree with Gasguru here far too many youngster/inexperienced people out there that want to charge the cust for their learning experience instead of for the job Its frightening what some people want to charge for a few hours work
  11. G

    What do you think? New boiler required

    Can see in the pics that it has been leaking service wont fix that
  12. G

    What do you think? New boiler required

    Have a look at boxt for changing it be cheaper than 3k
  13. G

    Boiler pressure rising to 4 when heating is on, PRV not kicking in, plumber thinks the pressure gauge is faulty, thoughts?

    what make and model of boiler do you have Expansion vessel probably needs recharging and prv renewing or freed
  14. G

    Failed TRV

    As per molerat but when you take the nut off get a small electricians screwdriver look inside the valve and where the pin sits give it a wiggle as that part of valve sticks on seating
  15. G

    American secretary of defence wears Russian flag tie

    even the pic on your link shows its a different shade of blue . Russian guy winding up the western press and Notch falls for it
  16. G

    Advice for new boiler in 3rd floor flat - scaffolding really needed?

    Yep baxi do an internal fit flue and so do some others i think . . This is one other thing that needs checking . https://registeredgasengineer.co.uk/technical/boiler-flues-in-high-rise-buildings/
  17. G

    Back 105 HE Correct Valve Pins

    it falls apart have a look at pic on this thread. https://www.diynot.com/diy/threads/baxi-105he-hw-problem.477857/#post-3848518
  18. G

    Back 105 HE Correct Valve Pins

    Yep venturis fall apart and can stop the diaphragm moving enough 24mm ring spanner required for changing them Then check in hole for any of the broken bits if there is tape a bit of garden hose to hoover hose and suck them out . . the venturi is on the lefthand side of the righthand brass...
  19. G

    Boiler Pressure Drop Only When Heating On

    when the heating has been on for about 20 mins check to see if pressure gauge is rising into the red if so expansion vessel needs recharging . .
  20. G

    90mm copper soil stack into clay

    Hope it wasnt the infamous Thrapston toilets ;)