Search results

  1. ianmcd

    Radiator thermostat valve does nothing

    you need to hold the valve , then turn the black ring nearest to the valve , it is spring loaded and it will come off, then you need to turn the same ring and you will feel a click, then push it back onto the valve, you have to do all this with the head set to max
  2. ianmcd

    Drayton Lifestyle LP722 timing issue

    are you sure it is not set to gravity ? post a pic of the rear of it so we can see
  3. ianmcd

    Radiator thermostat valve does nothing

    the sensor (the white bit) is not fitted properly, no tools needed just remove and fit back on till it clicks, turn it to max till you have fitted it correctly then turn it to off
  4. ianmcd

    Tribune HE Boiler not heating water.

    post pics of all switches and immersion heaters and controls
  5. ianmcd

    Has anybody have this radiator in their house? How is it?

    I fitted one of these recently in a mates kitchen, he hates it, a complete pain to fit, but at the end of the day it is your home, not a lot of heat comes out of them
  6. ianmcd

    Baxi HE tripping mcb

    Definately not the thermistor
  7. ianmcd

    Worcester Greenstar 24RI Burner Seal?

    get worcester to service it and you will get a warraty with the service
  8. ianmcd

    Mains HE24 flame failure on hot water only

    when you move to HW and it locks out, is the flame failure light solid or flashing ? if flashing is it twice per second or once every 2 seconds ?
  9. ianmcd

    What is this thermostat?

    It isnt a thermostat as such https://www.oeg.net/en/differential-controller-ksw-e-with-2-sensors-tf-pt-212000082
  10. ianmcd

    Boiler Service Warranty

    get Glow worm to service it and they will reinstate the warranty
  11. ianmcd

    Identify central heating programmer

    As others have said it is a Salus, replace as soon as you can afford to, they are absolute dire
  12. ianmcd

    Heating not firing up with thermostat

    be very carefull in who you get to check out your problem, your boiler is low voltage switching, which can be altered via a relay that the manufacturer will sell, but if you let someone mess around that doesnt know what they are doing will be expensive
  13. ianmcd

    Heating not firing up with thermostat

    as @stem says the channel plus H17XL is not a thermostat , it is a timeswitch, there will be a thermostst somewhere that isnt turned up
  14. ianmcd

    Gravity heating

    Rubbish you cant have a Y plan system with gravity HW
  15. ianmcd

    Halstead Ace High

    probably just the diaphragm very easy to change and only a few quid to buy
  16. ianmcd

    Identify this part

    Was your system solid fuel fired at one time, they used to be fitted with coal back boilers
  17. ianmcd

    Can a combi boiler diverter valve leak central heating water into domestic hot water?

    it is against site rules to Hi -Jack an old post, please start your own post if you want the correct advice
  18. ianmcd

    Vaillant boiler pressure range

    you need someone to calculate your water volume , you may need a larger expansion vessel, or the existing one is under charged
  19. ianmcd

    Parts for Vaillant Boiler (In Spain) (Ed.)

    it is called a piozo igniter they are very common, post a pic and I will send you a link where to get one there are a few different ones
  20. ianmcd

    Halstead Ace High

    well the heat has to go somewhere, turn the CH off and run a hot tap or the shower and feel the CH pipes below the boiler , they will be 22mm ones are either of them getting hot ? if so you have a diverter valve problem
Back