Search results

  1. ianmcd

    Recharging the expansion vessel

    Its cheaper that way :LOL:
  2. ianmcd

    Circulating pump keeps running

    You have just Hi-jacked a 16 year old post against site rules, please start your own post if you want the correct advice
  3. ianmcd

    Recharging the expansion vessel

    A very poor install, but the expansion vessel will never affect production of hot water, you dont have hot water is nothing to do with the expansion vessel
  4. ianmcd

    Back boiler overheat stat

    Hi Paul when it trips, feel the pump to see if it is running, sound like it is intermittantly sticking
  5. ianmcd

    Halstead Ace High

    Because it helps us diagnose what the fault is
  6. ianmcd

    Halstead Ace High

    does the flame go on and off when the hw cycles ?
  7. ianmcd

    Nest E & Baxi 228 OpenTherm issue

    Baxi 228 is a combi boiler, the nest E can not control anything to do with the HW temp it is simply a room thermostat and only controls the CH
  8. ianmcd

    Boiler making strange intermittent noises (see video link with sound)

    that is a hot water cylinder with an immersion heater with terrible wiring, it is not an electric boiler , that is something completely different, what pump are you referring to , there is no pump in your video
  9. ianmcd

    Advice on heating - boiler not firing when upstairs heating turned on

    Your zone valves are what are called MOMO (motor on, motor off) unlike the more common spring return valves , the motor on the upstairs valve has failed, you will need to replace with the same actuator, or repace the whole valve and alter the wiring, you wont be able to latch it open as...
  10. ianmcd

    Brand new heating system

    you cant just replace existing radiators with larger ones without correctly sizing the pipe runs to each rad
  11. ianmcd

    A lot of water coming from the overflow pipe and the boiler vibrating a lot

    The braided hose is probably from an earlier boiler install
  12. ianmcd

    Hot water thermostat loose

    Regardless of the HW cylinder stat, the HW can not get any hotter than the set temperature on the boiler, if it is getting hotter than the boiler is set at, then you must have turned the immersion heater on
  13. ianmcd

    Hivev3 wiring help replacing siemens rcr10

    that is possibly the worst wiring I have ever seen, what a disgrace
  14. ianmcd

    Glowworm Micron 30FF stopped working - fan/APS issue?

    yes on that boiler the front cover is the combustion seal, not on all boilers but on yours it is
  15. ianmcd

    Glowworm Micron 30FF stopped working - fan/APS issue?

    If you can access the fan then you have opened the combustion chamber on that boiler so sorry we cant give you advice on gas work it is against site rules
  16. ianmcd

    Hive Mini installation

    sorry I read it as terminal 3 , My bad mate
  17. ianmcd

    Baxi 105e flashing 60 fault

    The back micro switch as you call it is the pump proving switch, there is a small orifice below the diaphragm that needs cleaned
  18. ianmcd

    Hive Mini installation

    Yes it will but CH on with the dual channel is terminal 4 not 3