  1. ianmcd

    Baxi 105e Expansion Vessel failed?

    yes if it has two pipe connections it is the correct one the 105E only has one connection
  2. ianmcd

    Baxi 105e Expansion Vessel failed?

    All depends on the flue and clearance to the ceiling above
  3. ianmcd

    Odd voltage readings on 3-way valve & heating always on with hot-water

    I cant but it is on the side of the pump body
  4. ianmcd

    Baxi 105e Expansion Vessel failed?

    The instant uses the expansion vessel as a sort of pre heat store, the 105e expansion vessel will not fit your boiler they are different
  5. ianmcd

    Odd voltage readings on 3-way valve & heating always on with hot-water

    The arrow is on the side of the body, even if you turn the head through 180 deg it still pumps in the same direction , you only rotate the head to ease electrical connections, only the pump body decides the direction
  6. ianmcd

    Baxi 105e Expansion Vessel failed?

    Your boiler is a 105e instant, not a 105e, they are similar but not the same boiler
  7. ianmcd

    Odd voltage readings on 3-way valve & heating always on with hot-water

    On the body of the pump there is an arrow showing direction of flow, it should be pointing towards the inlet to the mid position valve, that pump looks to be fitted the wrong way round
  8. ianmcd

    Radiator brackets loose

    Totally wrong fixings used in the first place
  9. ianmcd

    Odd voltage readings on 3-way valve & heating always on with hot-water

    As @CBW some pics would help we need to see your wiring
  10. ianmcd

    Rad slow to heat up fully

    The baffle is inside the rad, do you know the make and model of the rad ? which pipe gets hot first left or right side ?
  11. ianmcd

    Hot water ok , Central heating not working

    is the boiler display showing the rad symbol when heating requested ?
  12. ianmcd

    How to Hive mini wire to Vokera Easi Heat 29c Boiler

    Follow the flex that supplies the boiler it will terminate in a bit of terminal block with a fuse in it attach the Hive L&N to the outlet terminal of that block and that way the hive receiver will have the added protection of the boiler fuse
  13. ianmcd

    Loss of hot water pressure in vented cylinder thermal store system

    The valve half way up the cylinder is a blending valve try that at max and see if the HW flow rate increases, beware though the HW might be really hot, just as a test
  14. ianmcd

    Loss of hot water pressure in vented cylinder thermal store system

    That should be fine, you have a restriction somewhere and it is usually that Pressure reducing valve, but I would have expected the dynamic (taps open) pressure to have dropped a lot lower than that if it was faulty
  15. ianmcd

    Rad slow to heat up fully

    Some vertical rads have a baffle and the flow must go into the baffle side or you will get the symptoms you describe
  16. ianmcd

    UFH and CH S plan

    Do you know if the existing thermostats have air sensors or NTCs inserted into the UFH ?
  17. ianmcd

    Loss of hot water pressure in vented cylinder thermal store system

    on the cold main inlet the valve with the guage on it is a pressure reducing valve, open two hot taps and tell us what the guage reads with the hot taps open full
  18. ianmcd

    Battery thermostat to Hive mini wiring issue

    NOOOOOOOO the two grey wires are permanent lives, DO NOT attach them to any Neutral
  19. ianmcd

    Three way valve and head - strange behaviour

    They were the origional W plan priority HW, only 3 wires and live for the motor was supplied from cyl thermostat satisfied, when power applied to the valve it motors into CH position, have only seen a few not very common, but are common in boilers with a small thermal store