    Placement of hot water cylinder and cold water tanks

    more or less the same set up ive got in my house matey !!! not sure about the salamander though ......cant remember if there good or crap but it started alarm bells ringing when i heard the name. 50 gallon tank in loft (mines on a stand) run down to cylinder in bedroom cupboard below. !!! good...
  2. T

    Placement of hot water cylinder and cold water tanks

    just a question......i thought ...as in most cases i see , the cold and hot feeds come from the same tank......... and the smaller tanks (as seen in the picture) is what i think is the F&E tank for the heating but it seems to me your talking like the cold water storage supply for the cylinder is...
  3. T

    Placement of hot water cylinder and cold water tanks

    the higher the tank the greater the pressure, if you thinking of putting a pump on your shower supplies then some have a certain height the tank needs to be above the pump to kick the flow switches in. i have heard of pumped hot and cold supplies on bath and basin but never a toilet, i dont know...
  4. T

    Baxi back boiler - Central Heating not working,hot water is?

    im not to clever with back boilers but is it a gravity system on the hot water ? if thats the case then your hot water will get hot if it fires up if not you may have a 3 port system or a 2 port system (one or two silver (could be white also) valves most of the time found in your cylinder...
  5. T

    FAO GAS BOYS: How do i get gas qualified?

    hey matey , my pal just qualified with two years of work experience under his belt. He went to the local training school and asked and they gave him a starter portfolio with pages of questions... some aout fires some about boilers ...servicing installing bla bla ....and told him to come back...
  6. T

    seized stopcock

    try getting a pair of grips on the tap head (the piece you grab hold of to turn) and tighten and loosen tighten and loosen, as slight as you can untill its closed fully, it may take five minutes but it works every time for me !!!
  7. T

    Baxi back boiler - Central Heating not working,hot water is?

    if the boiler is working ok and firing up after all the above check the pump as ive had it where the pump has packed up in a situation like this !!
  8. T

    cold radiator

    this also can never hurt a system if completed correctly follow the link below and this should help balancing a system http://www.diynot.com/wiki/plumbing:faq:faq2 :D
  9. T

    cold radiator

    yeah give it ago after a the heatings been running a bit , it wont hurt .
  10. T

    Installing a rad in the attic

    ahhhhh the amber necter !!!!!!!!!!!!
  11. T

    cold radiator

    try closing all of the rads except the offending rad and turn ya heating on, this should push any air locks through the rad !!
  12. T

    Installing a rad in the attic

    hahhahahha yeah grab yourself some inhibitor, fernox and sentinal are a few brands that i use (on every job) and pour into the pipe work you have just installed before you fill up, then sit back down and crack open a second tinny
  13. T

    Central Heating Pump Speed

    (most of the time) the pump pulls heat away from the boiler and pushes it into the system there will be a small arrow on the back of the pump to say what way it is going. try turning the pump up, whats the worst that can happen? it pushes over the open vent ? the way i see it is if there are 3...
  14. T

    Towel Radiator not working

    will i`ll be honest, if it is a one pipe system, then, if it was me i wouldn`t want the job. Im 31 and the amount of these systems ive seen i can count on one hand ...and the ones i have seen have been replaced for two pipe system(flow and return), as for the rad not working ...... try shutting...
  15. T

    Installing a rad in the attic

    turn off boiler, drain down system, tee off central heating pipes (flow & return) nearest the new rad,run flow and returns to new rad, in one end via a thermostatic rad valve and out the other via a lockshield valve(measure size for new rad so output is correct for room size) fill up heating...
  16. T

    High Boiler Pressure

    if your unsure about diy the best way i can think of is a rad bleed key, put it in one side of the rad at the top (there will be a square fitting to slot into that matches your bleed key) give it a quater turn, water should start draining out, it may take a while but this will bring your...
  17. T

    gasfitter screwed me over.....

    i agree it looks like a poxy installation, aint he heard of benders ??? i would defo get the fella back and say to him that u have an oven going there and could it be re-plumbed, it looks like he only took a few minutes piping it anyway
  18. T

    vented Hot water cylinder, CH works fine, only lukewarm DHW

    The problem was traced to a leak on the flange upstream of the pump which was replaced, at which point the system seemed to have worked fine for the last 2-3 week (save a tiny weep on a joint that drips like a thimble full over a day, waiting for folk to come back in january to sort it out...
  19. T

    ADDING A HOT WATER TANK TO A COMBI

    i've done exactly that but as i was restricted for money i put in a biasi !!! hahahha i used the hot from the combi to run my kitchen and run the flow and return from the boiler to a 3 port and cylinder, htg system and i know people have there own views on it ..." if ya gonna do all the put...
  20. T

    Nice easy "what is it question"

    there are a few different types of threads for these type of air vents as i've found out in the past trying to snatch a new one on !!!!! take a close up picture down to your plumbing merchants and ask for an air vent the same as you have, once you have it unscrew the new top..........begin to...