    london gas fitting

    hahahhah ......brilliant !!
  2. T

    Old Flue

    if your keeping it i would put a vent in just to keep the air flow through it as if its blocked it may start to sweat inside and cause all sorts of problems, if you want it removed i would consult a builder with experience of this type of job.
  3. T

    Maximum Boiler Pressure

    the P.R.V (pressure relief valve) is there to do a job. to stop the pipes in you heating system going popif the water over heats. Its the weakest piont on the system so normally around 3/4 bar the prv will start to leak to out side, which says its doing its job, when water is heated it will...
  4. T

    vented Hot water cylinder, CH works fine, only lukewarm DHW

    hmmmmmmmmmmm i thought if u had an airlock the hotwater would run dry ??????see if you have a 3 port valve or a two port valve, when you boiler kicks in on hot water check the flow pipe coming from the 3port or 2port going into the middle of the cylinder and directly below this should be the...
  5. T

    non draining c/h header tank

    it does sound like the cold feed is blocked if its a fairly new system it could be just blocked on the way down from the F&E tank you may not need to replace what was said above..... first id get a compression straight ready15mm or 22mm depending on size of the cold feed ( or if you can solder...
  6. T

    Please help, no heating despite three "repairs"!

    sounds to me that hes not a repair specialist, he could have disconnected the stat to see if that was the problem, the valve he talked about at the end is the diverter valve, i say to people if it make take time to get parts is that you can always get the boiler manufacturer out to repair you...
  7. T

    Cold radiator - help undoing Danfoss TRV PLEASE??

    eyyyyy there is no chrome nut....... its grey plastic ...and if moving the pin dont work ...try giving the valve a few taps from the side as this aslo frees the the pin !!
  8. T

    Problem Radiator

    hey mate ...im sure you may think there is no sludge in the rad but ..... if u know how .....pop it off the wall, connect a hose to one end and push water through it whilst tapping the middle and all around the cold areawith a rubber hammeror something that wont damage the rad, if then no cr@p...
  9. T

    Noisy Heating System

    hey fella the tapping could be due to the pipe work in the floor knocking against the joist as copper expands as it heats up. sometimes the noggings cut out for the heating pipework isnt large enough!! ho ho ho !!
  10. T

    Worcester 24I junior banging noise for 10 minutes

    check that the trv`s installed are reverse flow, if they are not, this can cause the banging on the heating system!
  11. T

    New electrics to outbuilding and shed

    what a jobs worth !! F.Y.I oharaf im just about to do a full rewire in my 3 bedroom house as being advised by my electricain friend !!!! who... at the end of the job will complete the final connections at the board and certify the job .....as i did to him when he wanted to put his own heating...