  1. adlplumbing

    Condensate pipe

    Is this the one on the boiler? If so please have checked out by an engineer, as it is linked directly to the flue. The water contains CO, this why it is acidic.
  2. adlplumbing

    Does anybody recognise this tap?

    There are cartirages, but not sure take it out, take it down. http://www.plumbcenter.co.uk/product/center-dual-domi-cartridges-3-4-(2-pack)/ I don't know if they are universal
  3. adlplumbing

    Does anybody recognise this tap?

    If your after changing washers, if it is not a quarter turn one. Then undo the metal sheath just below the handle where the spindle goes i to it, unter the will be a nut, undo that and you can get at the washer. turn water off first
  4. adlplumbing

    Gate valve as stop tap

    Done that got wet rip out team ripped one off, on the wrong side
  5. adlplumbing

    Gate valve as stop tap

    yes it may actually work,
  6. adlplumbing

    Moving Gas meter. Alternatives

    So who was that guy with me?
  7. adlplumbing

    Gate valve as stop tap

    Wow and I use to test them to 10 bar, on building sites as standard
  8. adlplumbing

    Gate valve as stop tap

    gate valve should be able to turn it off, if not use that to slow the flow and replace the iso valve with a proper stop tap.
  9. adlplumbing

    Moving Gas meter. Alternatives

    North you always need access to the primary ecv, and enough room to change it. Your best bet is to have the whole moved outside. See how much they would charge you for this
  10. adlplumbing

    Moving Gas meter. Alternatives

    http://www2.nationalgrid.com/UK/Services/Gas-distribution-connections/Alterations/ These guys can move it outside for you, and the ecv.
  11. adlplumbing

    Enclosing porch - issue with gas meter?

    if yu have any doubts, ring 0800 111 999 and jut say your unsure on the safety of the service pipe. An engineer will come round and have a look.
  12. adlplumbing

    Enclosing porch - issue with gas meter?

    make sure you can get to handle near the gas meter.
  13. adlplumbing

    Central Heating Repair

    Well my cats mad as he does not have any treats
  14. adlplumbing

    Boiler gas supply pipe sizing

    Gas sizing is a technical aspect of our trade, you are asking technical aspect of it. As such you may be trying gain technical help, to fit a boiler.
  15. adlplumbing

    Boiler gas supply pipe sizing

    .....and I'm not alone in thinking it!! Perhaps you should leave the gas work to the professionals that are qualified to do it. Haha, Oh okay, you must be right then. By your logic, any question posed about gas on a forum could be some numpty doing DIY gas work. A lot are, and seeing your...
  16. adlplumbing

    Boiler gas supply pipe sizing

    I was about to say the same thing, also he needs 26.6 mm pipe iron to get the best result.
  17. adlplumbing

    Coal-effect gas fire, flame height?

    have look at te instruction manual, and as the above poster said any concerns contact the installer first. Though some fires are designed to give of a yellow flame picture as they a for decorative effect.
  18. adlplumbing

    Where to get pilot solenoid for Gloworm Ultimate 80FF

    Sorry that is part of the gas valve, if you knew what you where doing you know where to get one from.