Search results

  1. M

    Core drilling for extractor fan

    What type and make of drill are you using???
  2. M

    My House appears Lethal - Any advise?

    Holmes have you been on the opium again :roll: :mrgreen: :mrgreen:
  3. M

    light problem upstairs

    Sorry yes on the up staits lighting circuit, isolate that circuit at the cu/fuse box first, and test that fittings etc. are not live, and then check the terminals are tight.
  4. M

    light problem upstairs

    Sounds like you've got a loose connection somewhere, either at a ceiling rose, a switch, or a hidden junction box. Start off checking the terminals are tight on any of these you find, in the area where the hammering was taking place.
  5. M

    Wiring in a frost stat and IR lamp in loft

    Why not run it off the same spur as your new light.
  6. M

    adding a loft light from a socket junction box

    Spuring off a radial is fine yes.
  7. M

    adding a loft light from a socket junction box

    Are you sure it is a ring final :?: Although ring finals are not against the reg's, in Ireland radials are the norm. If it is a radial it should be protected with a, 16A or 20A mcb(etc.) and spurring of it should not be a problem.
  8. M

    Replacing ceiling light and dimmer switch (novice!)

    The face plate of the switch must be earthed, if the back box is sunk into the wall, the earth wire from from face plate to back box, can be omitted. So yes you've got it right, moving the earth from the backplate to the faceplate.
  9. M

    Replacing ceiling light and dimmer switch (novice!)

    If there is only one cable yes. Yes!
  10. M

    joining 6mm twin and earth - drilled through cable

    Maybe you should have bought one of these off ebay: Then you could have accurately measured the strands, and worked out the csa of the cable. Edit: Is that better RF.
  11. Untitled

    Untitled

  12. M

    Snapped wire in 60s light switch

    That looks like MICC (aka pyro) to me, which means you don't stand a chance of DIYing it, look up micc in the wiki to see what you are up against.
  13. M

    Pressure cooker and induction hob

    Pressure cookers have two pressure relief valves, one being used to maintain a fairly constant pressure whilst cooking, the other is a safety valve, which remains closed in normal use, and is set to open above normal operating pressure, but below dangerous levels. The safety valves are designed...
  14. M

    Led technology...

    Apparently not :!: I think we all would of guessed, that if you pulverize a LED or two, it's not really a good idea to eat the bits :roll:
  15. M

    Looking for a time delay lock out

    How silly of me, that would be better. Don't know why I didn't put it there, probably due to beer and tiredness
  16. M

    Looking for a time delay lock out

    should do the trick, providing the timer relay set at 1min opperates a nats chuff, before the other one.
  17. Untitled

    Untitled

  18. M

    Patch Panels.

    St. Louis, Missouri. apparently http://royal.pingdom.com/2008/01/09/the-worst-cable-mess-ever/
  19. M

    ford focus 06 tdci won't start unless full of fuel

    Sounds like you've fitted the wrong fuel filter, some have a valve in to stop the fuel, draining back into the tank when the engine is not running, i'm guessing you've fitted one without, and it's got to suck the fuel back up the line, after it's been left for a while.