  1. O

    15th/16th

    Thats cleared that up then thanks Dingbat.
  2. O

    15th/16th

    OSG arrived yesterday. Bonding all done in 4mm ? If theres no shaver or heater is it linked up to the pull cord or bathroom light and if so do you still use 4 mm Is there some confusion as to some of the bonding being above or below the floorboards ? I'm sure I read somthing about it...
  3. O

    15th/16th

    Thats cleared that up then, now what about the bonding I take it the pipework is bonded as per normal but are the radiators in the Bathroom/en suite then bonded back to these or where ?? And yes in Ireland its called the Bathroom/en suite :)
  4. O

    15th/16th

    oops!!!! you guys might know it as something else, but it was the small space that contained the hot water tank along with an emersion heater and some shelves and the woman of the house would put towels and socks and all sorts of items in there to keep em warm. Don't they make them any more ...
  5. O

    DIY fit of Burglar alarm.

    Did that cost much. How did you go about it and does an approved firm have to maintain the systemafter approval. Reason I ask is if I installed the alarm system say in a new build along with the electric installation could I then get it approved by NACOSS and handed over to an approved firm for...
  6. O

    15th/16th

    Can't get into the debate about the (Name) but 6mm was used back to the Board and the main water supply "so its now 10mm ok.." you also installed an earth rod on some installations.AFAI Remember you bonded the hot & cold pipework together in the bathroom but it did'nt have to be bonded to the...
  7. O

    DIY fit of Burglar alarm.

    I fitted loads of systems using the ADE Accenta panel, the RKP is neat and tidy for fitting near the front door fitted them with the Medusa PIR, never had a problem with them and never had false alarms. Bought most of them from Moreton who are very good. Put one in my own house 4 years ago and...
  8. O

    DIY fit of Burglar alarm.

    Don't mean to but in but as far as I know you can't get a system hooked up to one of these alarm control centrers unless the installer is NACOSS approved. All modern alarm panels have the facility to hook up to a dialer but the approval bit kinda cuts out the diy guy :( I'm sure I'll be...
  9. O

    15th/16th

    You have'nt used The Electricians Guide by John Whitfield by any chance ?? they say its better than the on site guide I have it ordered along with the Regs but I won't get it untill after Xmas
  10. O

    15th/16th

    As I said in my original post V Drop, length of cable runs, bonding was only done in the hot press you did'nt have to assume someone was going to stick in a couple of 500 watt lights after you finished the job and if my memory brain cells have'nt been damaged by to much alcohol over the years...
  11. O

    15th/16th

    Only joined and I've learned something already Thanks
  12. O

    15th/16th

    Hi all Just joined up and am seeking some advise on the Reg's. When I was doing my City-Guilds I done the IEE 15th edition and spent 2 years at college doing it whilst on day release. A few years after finishing my App I give up the tools "got fed up with some lousy employers and working on...