  1. swbjackson

    New combi boiler - advised I need to change my shower cartri

    Mira 88 doesn't have a cartridge. Have a look at http://www.showerdoc.com/mira-88-post-1984-shower-spares. It's a manual mixer so may not achieve stable temperatures on a combi boiler if other outlets are opened.
  2. swbjackson

    Valve to shut off hot water output from Megaflo cylinder

    Expansion doesn't take place in the pipework, the pipework doesn't stretch. Expansion takes place in the expansion vessel or air bubble. No problem fitting isolating valves on the outlet of an unvented cylinder. The only place you shouldn't fit valves is between the cylinder and the expansion...
  3. swbjackson

    What Combi boiler type question?

    I can run the hot tap in the kitchen and run the shower at the same time on a 40Cdi. Flow rate is around 16 l/min but I have a good incoming cold water flow rate and have got flow restrictors fitted to all outlets. Without the flow restrictors it's entirely possible that one outlet will starve...
  4. swbjackson

    Making Sure you have no air locks after fitting a pump

    So if you can't access the pump to bleed it how do you access it to change it when it burns out? In my 32 years in the industry I've never had to add washing up liquid to a system.
  5. swbjackson

    Central heating off limits for DIYer?

    A useful tip from me is don't come onto a site asking for advice and then alienate all the professionals by insinuating that they are over charging. Just give it a go, what's the worst that can happen? It'll only cost you a few thousand to replace your boiler if you destroy it.
  6. swbjackson

    Potterton EP2001 replacement with EP2

    After replacing two EP2002s that developed faults within a couple of weeks I swapped to a different make. Means changing the back plate but no problems since.
  7. swbjackson

    Shower water supply and Combi

    An ex Aqualisa rep told me to fit a ballofix valve to the cold feed and restrict the flow with it when i enquired about replacing the cartridge in an Aqualisa shower for the combi one. Apparently the only difference is a flow restrictor in the cold.
  8. swbjackson

    Icos HE12 - A quick question if I may

    More likely to be an issue with the controls than the boiler. I would suspect a sticking microswitch in one of the zone valves.
  9. swbjackson

    Constantly bleeding...

    It could be pumping over or drawing air down the open vent. If it's got worse since the new pump went in it's possible because the new pump has been set at a higher speed.
  10. swbjackson

    flowmax tank high pressure in hot

    How are you testing the pressure? Could be a faulty gauge 15 bar is one hell of a pressure in a domestic plumbing system. I'd be suspecting a failed mini expansion vessel if one is fitted.
  11. swbjackson

    Radiator inserts

    You can get fixed rad extension pieces from 20mm up to 50mm. I think Armo74 is thinking about the extending ones, I've never had problems with the fixed length ones.
  12. swbjackson

    unsafe installation?

    It's definitely one that needs reporting to gas safe. You do need to be registered to work on LPG. From your description I would classify the installation as At Risk and shut it off. I would advise her to shut the gas off at the bottle and report the installer to gas safe ASAP. This guy needs...
  13. swbjackson

    Can anyone please tell me what this is?

    It's a non return valve, presumably to prevent reverse or gravity circulation.
  14. swbjackson

    Glowworm compact 80e boiler pressure keeps rising.

    I'd drop it lower than 1 bar as it will be easier to see any rise. Just shut off under the boiler. If you turn the boiler back on the expansion of the water as it's heated will make it difficult to tell if there is a problem.
  15. swbjackson

    Glowworm compact 80e boiler pressure keeps rising.

    Drop the pressure, turn off boiler, isolate the cold and see if the pressure still rises. If it doesn't turn the iso valve back on and see if it goes up. If it does it's probably the secondary HEX
  16. swbjackson

    Painting Radiators

    It also tends to yellow with the heat. Best way is an aerosol of radiator enamel and mask up around it well.
  17. swbjackson

    Combi Question

    Expansion inside the tap is it warms up.
  18. swbjackson

    combi boiler installation - hot water to kitchen sink

    It's always good to minimise the route that the water takes to save wasting water and delays in getting the hot water to the outlet. After a hot water draw off the water will sit in the pipe and cool down. Next time an outlet is opened you draw off this cold water before the hot comes through so...
  19. swbjackson

    Rainwater harvesting

    I'm thinking a flat brass bar with a hole drilled either end. One end on the arm of the valve with a nut holding it in place, other end with a bolt through attaching the float to it. Solder or braize the top end to stop it pivoting and you've probably achieved it for about £20.
  20. swbjackson

    Alternatives to LST Radiators

    Be wary of using products that haven't been tested as you may be held liable for any injury. Have a look at http://www.coverad.co.uk/