  1. swbjackson

    Where can I get this hook?

    If it snaps that easily I wouldn't be sticking a child in it.
  2. swbjackson

    Cannot get HW by itself since motorized valve replacement.

    [/url] The Drayton TA/M4 valve is used with a special relay box. A standard 3 port valve is not a direct replacement unless the system is rewired to a standard Y plan configuration. If the junction box says RB1 or RB2 on it the chances are the wiring is incorrect. As Tony (Agile) said...
  3. swbjackson

    How to avoid copper pipe crinkling during bending

    The crinckling is known as throating and will happen with a rubbish bender or with a poorly maintained bender. It is also a lot more likely to happen with continental copper tube which seems to be a lot harder than the normal half hard copper manufactured in this country. The main cause with...
  4. swbjackson

    Dimplex unvented direct water heater

    You need to be G3 qualified as the immersion heater is a safety critical part.
  5. swbjackson

    New boiler was chem flushed at installers recommendation

    If the installer is unwilling to rectify the gas pipe sizing issue give Gas Safe Register a call and ask for an inspection. They will normally insist that the fault is rectified.
  6. swbjackson

    De-butchering the gas

    Running the gas pipe is considered gas work and should only be done by a gas safe registered installer. Your best bet is to get a local installer to come in and disconnect or cap off any gas pipes to allow you to do the rip out and then get them back to run the new piping.
  7. swbjackson

    Pressure increase in unvented hot water cylinder

    Any form of outlet that mixes hot and cold is liable to give problems with unbalanced supplies. Easiest solution is to limit the cold as well to give equal pressures. Ideally the shower should be fitted with single check valves on the inlets as well.
  8. swbjackson

    Replacement combi boiler

    I think one of the reasons that the smaller firms and one man bands like manufacturers like Intergas is the back up they get. The large firms like Worcester Bosch, Vaillant etc. are only interested in supplying the big boys and don't give the back up to the small firms. I for one have moved away...
  9. swbjackson

    Central Heating - variable radiator heat

    The bypass valve ensures a minimum flow through the boiler. We really need more information on the system though. Is it fully pumped? S plan (2 motorised valves, one for heating, one for hot water). Y plan (Single valve with 3 pipes coming out of it). Also is it a single pipe or two pipe...
  10. swbjackson

    Issues getting hot water.

    Hot water off time means the manual has been badly translated. Hot water off time is when there is no call for hot water. You've got a fault with the boiler which require s a gas safe engineer to rectify. Get someone in to check it over.
  11. swbjackson

    Gas leak in newly purchased house!!!!

    I think the term is caveat Emptor, buyer beware. I always advise people to have the gas, heating and plumbing inspected before they buy a property. Most don't and are then shocked when I turn up to service the appliances and shut them off as being unsafe. The fact that the guy was unwilling to...
  12. swbjackson

    Rated People any good?

    I'm with Checkatrade and find it very good. I probably get around 75% of my work through it at the moment and most of the customers use me again. It's an annual fee which, to me, is a very effective form of advertising. It's a lot cheaper than advertising on Yell etc. For the customers, they can...
  13. swbjackson

    BACK BOILER CONDEMNED - WHICH COMBI?????

    Make sure that you tell the guy doing the work this before he prices the job. I use the value of the scrap on a job to offset the cost of rubbish clearance so will charge accordingly more if the customer wished to keep the cylinder.
  14. swbjackson

    Ideal logic+

    You've got to weigh up the inconvenience of waiting for the water to come through versus the cost of keeping the boiler warm at all times. If you have a water meter you then add the cost of the water wasted to the mix.
  15. swbjackson

    German 1/2" TRV body onto 15mm copper pipe ok?

    A google search brought up loads of brass TRVs. https://www.google.co.uk/search?q=brass+TRV&ie=utf-8&oe=utf-8&aq=t&rls=org.mozilla:en-GB:official&client=firefox-a
  16. swbjackson

    Searching for Small Stainless Steel Sink

    Have a look at Blanco sinks. I've got one in my utility room and the bowl fits into a 400 unit and the drainer is above the washing machine. By cutting a section out of the back of the unit I just managed to squeeze a monobloc tap with flexi tails in.
  17. swbjackson

    Bronze pump DHW circulator

    Probably cheaper to fit a small undersink electric unvented unit. No heat loss from circulating water, no disruption putting the secondary return in.
  18. swbjackson

    Pulling old lead pipes replace with MDPE

    Won't work. Have you seen the kit they use to mole a new main in. It runs off a huge compressor. Do you think they'd bother with that if a small hand puller would do the trick?
  19. swbjackson

    What cordless combi drill for an ocassional DIY'er please

    For twice a year buy a corded one and an extension lead. Leaving a battery 6 months between uses doesn't help it's longevity.
  20. swbjackson

    Boiler working too hard equal high bills

    You, and your supplier, are getting two different things mixed up. When an engineer talks about pressure drop across a pipe run he is talking about the frictional losses that occur when gas passes through the pipe. The regulations state that this should be a maximum of 1 mbar between the meter...