  1. swbjackson

    Can gas pipe develop crack on its own?

    If you don't get anywhere with them I will happily repeat what I have posted above on headed paper and sign it for you.
  2. swbjackson

    Can gas pipe develop crack on its own?

    Don't take it on the chin. It is not your fault. They are trying it on.
  3. swbjackson

    Can gas pipe develop crack on its own?

    It's possible that when you disconnected the cooker you disturbed a joint but if the joint had been correctly made in the first place you would struggle to put enough mechanical force on it to damage it. They are talking hogwash, tell them that you are not willing to pay for a problem which...
  4. swbjackson

    Connecting bidet spray to mains pressure

    No but accidents happen. Most people don't deliberately drive there nice shiny cars into the back of the one in front but it happens. The water regulations are there for a reason. It is to protect the water main from contamination and prevent wastage.
  5. swbjackson

    Connecting bidet spray to mains pressure

    It is no greater risk than a shower hose or extendable sink tap hose or any other hose when they are not fitted in accordance with the water regulations. The issue comes with the fact that as a bidet shower it will be designed to be used over a toilet pan which is a fluid category 5 risk. If the...
  6. swbjackson

    Central Heating Filters

    Bigger back hander from Spirotech?
  7. swbjackson

    Tiling disaster....didn't even get as far as the DIY....

    There's normally a notice advising people to ask for assistance with heavy items. Someone handling an item without the correct PPE will normally result in any compensation claim being massively reduced anyway. It makes me cringe when I'm in one of the sheds and people are moving heavy...
  8. swbjackson

    Poor heating circulation

    I had a similar problem on a sealed system. I couldn't get half of the system to work unless the lockshields on the other half were barely open. It was so critical that a fraction of a turn too far would stop the other half working. Fortunately the system was split in the airing cupboard and I...
  9. swbjackson

    S Plan Help

    Have you got the blending valve etc. for the underfloor?
  10. swbjackson

    Do I need a flue inspection hatch?

    Have a look at http://www.gassaferegister.co.uk/advice/flues_in_voids.aspx On this page you will find the words Your warm air unit is not a room sealed appliance.
  11. swbjackson

    Strange valve? underneath bath

    It could be a pressure reducing valve. Are you on mains cold, tank fed hot?
  12. swbjackson

    Heating only fires when tank stat in on..

    I'd guess at a wiring fault. Orange is switched live to boiler.
  13. swbjackson

    Fitting a soil pipe through a joust

    This forum is not the correct place to be asking how to do the work. You need a structural engineer to advise on how to safely carry out the work. When you and your neighbours start to get structural cracks using "an internet forum said it would be okay" isn't going to stand up as an argument...
  14. swbjackson

    Shower leak

    Your husband is correct. Most shower enclosures should be sealed all of the way round the outside and down the sides inside but leaving the bottom inside free of silicone to enable any trapped water to escape.
  15. swbjackson

    Correct wrench/pliers for the job?

    Most installers throw those connections away and use an easy fix kit. They are the work of the devil. http://www.amazon.co.uk/MX-Easy-Thermostatic-Mixer-Showers/dp/B006UFGS32
  16. swbjackson

    which pressure booster pump will work.

    Look for a negative head pump. Check with manufacturers that it is suitable for use to boost individual supplies though as a lot of twin impeller pumps are not suitable.
  17. swbjackson

    Is there a shallow wastetrap suitable for a washing machine?

    Fit an S trap or use a 42mm hepVO valve with a running adaptor.
  18. swbjackson

    Boiler flue new regs

    You need to be able to inspect every flue joint so it depends what length flue extensions have been used.
  19. swbjackson

    Stop tap requirements

    AS long s the full bore valve is WRAS approved there's now no problem fitting them.
  20. swbjackson

    Drill for 4" core drilling

    Is it too late to sue Makita under the trades descriptions act? The 8406 is an excellent drill for coring.