  1. P

    Shower pump connected to bath mixer tap?

    Yes it can and it will give you a quick filling bath
  2. P

    Shower identification

    Hi Can anyone identify this shower? The thermostat has given up and I have tried many ways of identifying it with no luck. Thanks in anticipation. Steve
  3. Untitled

    Untitled

  4. Shower

    Shower

  5. P

    Slow draining basin waste

    Swap the trap with one that has an air admittance valve. This should cure your probmem.
  6. P

    some rads not getting hot

    Did you vent the pump when you re-filled the system. If not, with the heating system off, open the screw in the center of the pump until you get water
  7. P

    Baxi combi - pressure building

    Check that the filling loop is completely closed, disconnect the flexible hose if possible.
  8. P

    Mapp gas

    Propane is much cheaper and more than adequate.
  9. P

    issues with a bleed valve (radiator removal)

    The radiator will not shut off if the head is missing from the thermostatic valve. You get a special plastic cap with the valve when purchased that you screw on the valve in place of the head. You could take a head from another radiator, presuming that they are the same but be very careful as...
  10. P

    Hot water through a Megaflo moosoon sealed vented system?

    It's not about pressure more so flow. Unless the flat is enormous, it would be unlikely to have a bronze secondary circulating pump installed. I agree it would be pointless not using the balanced cold water supply available, but I still think that you have a pumped gravity cold water supply Steve
  11. P

    Hot water through a Megaflo moosoon sealed vented system?

    Hi Without knowing more details it appears that you have a Megaflow unvented hot water system providing hot water at 3.5bars to your hot taps and a Monsoon pump that is boosting the stored cold water from the storage tank. Flow and pressure permitting, it would have been better to supply the...
  12. P

    Grundfos 15/50 pump

    Because if it was a combi or system boiler the pump normally has an AAV :wink:
  13. P

    Grundfos 15/50 pump

    On the flow pipe that goes into the cylinder. You should see 2 pipes one about 12 inches above the other to the side of the cylinder. There should be an air vent on the top pipe. It may need a radiator key or it may be just a thumb screw.
  14. P

    Hot water in shower slowly reduced to trickle.. help please!

    Take the silver flexible hose off at the shower valve end, turn the shower on and see if you get flow.
  15. P

    Grundfos 15/50 pump

    Did you vent the cylinder coil?
  16. P

    A new problem every day.....?

    Make sure that the valves either side of the new pump have been opened fully as a start.
  17. P

    dishwasher keeps filling even when off

    It's most likely a faulty solenoid valve and it's letting by. The aquavalve is also a solenoid valve but it's purpose is to shut off the water supply should the supply hose burst. Follow the water mains supply into the washer and there will be a small in line valve with wires attached. You can...
  18. P

    Need help on changing washer on tap

    As Hugh says, these taps have a small slotted grub screw on the side of the head. This secures the head to the valve spindle. As a tip - put the plug in the sink in case you drop anything. Steve
  19. P

    looking for recommendations for installer of avanta my area

    PM me. I can give you a quote and I live between Bromley and Orpington.