  1. P

    Glowworm 30si - pressure loss

    MM Put a plastic bag over the external outlet of the prv pipe for a day and see if you collect any water. Does your pressure rise significantly when the boiler is in operation? Gooba Your expansion vessel is most likely fooked. The cheap alternative, as suggested is to fit an external one...
  2. P

    Latest Keston boiler stolen!

    The police should check the local garden centers as it might be being used as part of an irrigation system :D :D
  3. P

    VaillantEcotec plus 837

    You only have one water main comming into your property (I assume). When the hot tap is open you will get the full flow through the boiler to the tap. When you open a cold tap in addition the water flow will be split between the two and therefore the flow reduced to both taps. There are other...
  4. P

    Glowworm 30si - pressure loss

    The expansion vessel should not be full of water. There is a diaphragm inside and if you momentarily push the center of the schreader valve you should hear a small amount of air escape. If wheen you do this you get water, you will need a new ex vessel or fit one externally. If the diaphragm is...
  5. P

    Mixer shower flow rates: Advice please

    The normal shower delivery should be around 13 l/min so looking at your figures, it looks ok. Take a look at the Aqualisa digital Quartz combined bath filler/shower. If you can afford this product, it is money well spent and comes with a 5 year guarantee.
  6. P

    Bosch Worcester 28i Junior Combi Pressure problem

    See FAQ about re-pressurising expansion vessels and testing if it is knackered.
  7. P

    Advice on the new Baxi Bermuda BBU 15 HE condencing boiler

    It has an internal condensate pump also.
  8. P

    Halstead Gold - isolating water from within the boiler

    My strongest advice is to get the plumber out of your house ASAP and get somebody that knows what they are doing :shock:
  9. P

    gate valve versus ball valve

    Ball valves sometimes have a tendency to leak from the spindle. If you decide on these you should ensure that you purchase full bore ones or you may suffer from flow problems.
  10. P

    Radiator connections

    The thread size is normaly 1/2" BSPT and I assume you refer to valves with a built in drain cock. You will need a special allen key (Available from plumbers merchants) to remove the old valve and a spanner to tighten the new TRV. You will need to fit an auxilary drain cock assuming that the...
  11. P

    Boiler making noises after drain and refill of system

    After would ensure that there is no air in the pump.
  12. P

    potterton profile 80E boiler electrics problem

    it sounds as if you have created a second problem. I think that you may be looking at a new pump and most likely a new fan. The fan will need to be changed by a RGI as it forms part of the flueing system.
  13. P

    Which one of you lot have done this masterpiece?

    My guess is the electrician in order to get the socket where he wanted it :lol:
  14. P

    Boiler making noises after drain and refill of system

    Persist with the screw in the centre of the pump - it opens anti clockwise. Do this with the boiler off and until you get a small trickle of water out. When filling the system, vent the downstairs rads first. Steve
  15. P

    chaff maury britony se80

    I would have done it for a tenner :D :D :D
  16. P

    Putting aditional radiators in - will this work??

    Looks ok to me. What sort of boiler/system do you have
  17. P

    problem with heating

    Did you vent the pump once replaced? The pump is knackered and needs replacing.
  18. P

    Protection from Theft / Vandals

    How about using anti vandal paint - the stuff that remains sticky
  19. P

    Incoming mains...Alkethene?

    The problem is not getting the fitting but getting the insert. I had to get one made on a lathe when I had a similar problem.
  20. P

    One of the rads is not working?

    Open the lockshield valve a little.