  7. gas_man_gaz

    Need advice on fixing an Ideal Classic boiler

    i agree keep the classic, its a top boiler. id also ignore everything your independent engineer has told ya. very unlikely that something has leaked onto the pcb. why would the bg eng advise on a powerflush then? he's more likely to advise not all the parts are available/new chb (depending on...
  8. gas_man_gaz

    Central heating broke! Any help greatly appreciated!

    Oops got the wrong pump, still willing to bet it's knackerd tho! :lol:
  9. gas_man_gaz

    Central heating broke! Any help greatly appreciated!

    No it won't be a problem... wen bg turn up just make sure ya tell um what ya fiddled with as the system might not work as it should if the gate valves are set incorrectly.
  10. gas_man_gaz

    Central heating broke! Any help greatly appreciated!

    If you are not getting a digital reading on the pump when there is power to it then the pump will be at fault.. The red things are gate valves, stop messing with them or ya could be creating more faults. The pics are too close to say what pipes they are on but I'd guess a balancing valve for...
  11. gas_man_gaz

    Central heating broke! Any help greatly appreciated!

    If the pump is workin the pump should display a number, Try unplugging the pump and re-fitting the wire.. To me it does Sound like the pump has gone tho (I've changed loads of these recently) just ensure you are gettin power to it before replacing it.
  12. gas_man_gaz

    Central heating broke! Any help greatly appreciated!

    Are you sure the pump is running? With the heating and hot water on what does the pump display? If it is running try setting it to manual 3 to clear any air ( use the > button)
  13. gas_man_gaz

    ideal elan casing seal

    By any chance is the reason you fitted and carried out all your own repairs to your central heating down to you having such a **** attitude to people trying to help you? If I pulled up to carry out some work and you was spouting off like you are on ere I wouldn't even bother getting the tools...
  14. gas_man_gaz

    For anyone interested I still have the gas valve, if anyone wants to contact me please send me a...

    For anyone interested I still have the gas valve, if anyone wants to contact me please send me a private msg or email as I don't get notifications to profile comments, cheers
  15. gas_man_gaz

    Glowworm bolier- recurring fault 22

    If Iam right, yes it is. will cost a bit n all! Best getting a fix price repair from glow worm imo
  16. gas_man_gaz

    Glowworm bolier- recurring fault 22

    Why does it matter if its a combi? From what you describe it sounds like the main heat exchanger is leaking.
  17. gas_man_gaz

    Wireless roomstat for conventional boiler

    Don't think so, your supplier wouldn't have any effect on a upgrade price anyway, being a homecare customer might do tho. Give um a ring and ask for a quote, but Iam 99% sure that would be the price.
  18. gas_man_gaz

    Wireless roomstat for conventional boiler

    bg have currently got a offer on the "remote controls", its basically the same set up as the wireless controls but you can use a app on a smart phone or txt it to control ya ch. they are currently £150 fitted.
  19. gas_man_gaz

    Sensor on front of Ariston Eurocombi A27 diverter valve

    the part with the rusted screws is ya primary flow switch, which is ok or the boiler wouldn't fire up