Search results

  1. gas_man_gaz

    Ideal Boiler LE fault NOT PCB

    Who replaced the pcb? Was it replaced with a brand new one from a parts suppliers? Was the position of the jumpers checked or did they just copy the position on the old pcb?
  2. gas_man_gaz

    glow worm 65 80B gas valve

    yep still got it
  3. gas_man_gaz

    Wireless programmer not Linking to boiler

    ya right if the receiver is shot it wont override but where does the op state that the the receiver is getting a signal and the green light is on? if the stat is at fault you can override at the receiver. imo if the batterys been out and he has more than 1 wireless control i think pairing the 2...
  4. gas_man_gaz

    Wireless programmer not Linking to boiler

    to pair the stat and the receiver -Turn the power off at the spur and remove batteries from the stat. -Switch power back on, then press and hold both buttons on the receiver, should flash red then stay illuminated. -Let go and put the batteries back in the stat and turn the stat up and down...
  5. gas_man_gaz

    Wireless programmer not Linking to boiler

    to override there is a button on the receiver, this can be used to the prob is fixed. have you tried pairing the stat and the receiver? i would try this first but if they do need replacing its only a 5min job (swapping like for like)...
  6. gas_man_gaz

    Gloworm 24cxi F5 overheating....

    have you had it serviced in the last few years? they need a modified burner door seal fitting. if you haven't this could be causing the boiler to go to overheat also sounds like it needs a new disconnecter, they are crap but tbf most of the boiler is :roll:
  7. gas_man_gaz

    Boiler Wiring Connections - Worcester 18RI Condensing Boiler

    tbh if ya asking this ya should get someone in to sort it. but if ya want to have a go... permanent mains supply to ya l on st1 pump needs to be wired to the boiler on st2 (Lp being the live) the orange from the wiring centre needs to be wired to Lr (also on st2)
  8. gas_man_gaz

    British Gas fixed price repair cover for potty profile

    fix price repairs only cover 1 fault (unless related) so id charge for both! :twisted: £199 for gas valve then £79 for the pcb
  9. gas_man_gaz

    ideal isar 24he, making a over gas sound.

    if it sounds like a fog horn check the trap/condensate isn't blocked, the sediment from the heat exchanger drys rock hard so ya might need to replace the trap
  10. gas_man_gaz

    Pump constantly on, what could be wrong?

    even agile is catching on :lol:
  11. gas_man_gaz

    Pump constantly on, what could be wrong?

    you should have a bit of resistance on the lever, isolate the power remove the head and check the spindle and the head isn't stuck
  12. gas_man_gaz

    Pump constantly on, what could be wrong?

    isolate the power to the entire central heating system and check the valve again
  13. gas_man_gaz

    Pump constantly on, what could be wrong?

    :lol: might try that the comment about 2 screws securing the head would also give the op a clue :wink:
  14. gas_man_gaz

    Pump constantly on, what could be wrong?

    if you turn the power off to ya central heating at the fuse spur does the newer valve (the 1 with no resistance on the lever) spring back?
  15. gas_man_gaz

    Pump constantly on, what could be wrong?

    yes, if it has a dimple on the silver cover it can be removed without getting wet. they will be 2screws securing the head to the valve body, isolate the mains if you do attempt to check this. honeywell valves rarely become stiff tho. i would check the orange wires from the valves to see if...
  16. gas_man_gaz

    Cloudy hot water

    not quite http://www.worcester-bosch.co.uk/homeowner/customer-service/faqs/general-boiler-questions/why-is-the-hot-water-produced-by-my-combi-boiler-sometimes-cloudy
  17. gas_man_gaz

    Cloudy hot water

    norm its just air bubbles in the water, it will settle down with use
  18. gas_man_gaz

    Pump constantly on, what could be wrong?

    at a guess id say its the sunvic motorised valve (the white 1) is at fault, either the microswitch stuck on or the valve spindle stiff. try removing the head and checking that the spindle is free, if it is isolate the power and remove the orange wire make safe and test op
  19. gas_man_gaz

    FAO AGILE -Gem combi boiler

    i am sure the op is over the moon to finally see your response 4 year's on :lol: