  1. gas_man_gaz

    RC Plus/WR1 - Problems Starting Boiler

    Wen you operate the stat does the receiver flash then turn green? If so can you hear it click wen it does?
  2. gas_man_gaz

    RC Plus/WR1 - Problems Starting Boiler

    Sounds like the receiver may be shot but before doing anything try this. Turn the power off at the spur and remove batteries from the stat. Switch power back on, then press both buttons on the receiver, should flash red then stay illuminated. Let go and put the batteries back in the stat and...
  3. gas_man_gaz

    best value for TRV installation? DIY or Fitted?

    bg charge slightly less for energy saving upgrades, but will still be expensive :lol:
  4. gas_man_gaz

    boiler will not light

    id guess at the aps :D
  5. gas_man_gaz

    Struggling with hot water temperature and system generally

    haven't had much to do with solar so its a bit of a guess, but has it got a blending valve which is mixing ya hot water a little cooler than you would like? have ya got any pics of the sys?
  6. gas_man_gaz

    Boiler not firing. Pump constant run.

    id guess a blocked cold feed, sounds like ya pump is running but the water isn't circulating correctly.
  7. gas_man_gaz

    replacing Back boiler & primatic cylinder new system.

    it sounds like you could fit the combi in the airing cupboard where the cylinder is without making too much mess. you would have the hot/cold feeds and pipe-work for your central heating as they all would be used for your cylinder. you would need to get the gas supply in there but that could be...
  8. gas_man_gaz

    sludge cleaner

    id phone a different plumber :lol:
  9. gas_man_gaz

    replacing Back boiler & primatic cylinder new system.

    is the airing cupboard on a outside facing wall? and where is the gas meter located?
  10. gas_man_gaz

    Boiler Replacement

    what model boiler is it? eg vaillant turbomax??
  11. gas_man_gaz

    Central Heating/Hot Water Replacement

    if theres enough in the budget id also go for a unvented with a worcester ri boiler
  12. gas_man_gaz

    Wireless thermostat on Glowworm Ultimate 80FF?

    the wireless stats they use are similar to these :wink: http://www.screwfix.com/p/drayton-digistat-3rf-room-thermostat/76816;jsessionid=GvRbQLDZY24kmJwYySlrpmJh0RnPhKGyQXlvRBLGV4LxJGyClTMc!-1047906746
  13. gas_man_gaz

    Ideal isar again

    ya mean - - - or - - -
  14. gas_man_gaz

    Ideal isar again

    its overheated
  15. gas_man_gaz

    Wireless thermostat on Glowworm Ultimate 80FF?

    bg will fit ya wireless controls what ya can use with a app on ya phone for around £200 :D
  16. gas_man_gaz

    Identify TRV manufacturer

    prob be the valve itself that is passing, be easier to change the entire valve
  17. gas_man_gaz

    British Gas Worcester C1 combi boiler - pressure always high

    if the vessel has gone and the prv is dripping i think the op would be having to top the pressure up, not let it out! :roll: sounds more like either the fill loop is passing or the heat exchanger has gone, stick with bg :wink:
  18. gas_man_gaz

    Vokera Compact boiler problem

    id sort the sys pressure out 1st so that can be ruled out. on some vokera's the fill loop is on the cold mains valve (easy way to tell is if the valve has a black lever, turn it till it faces the opposite direction and see if it fills up) or take a pic of the underneath of the boiler and post it
  19. gas_man_gaz

    Which Combi Boiler??

    whats ya budget? :lol: