  1. L

    Biasi 24s cutting out intermittently

    HI printed circuit board,brain of the boiler .
  2. L

    sime super 90 plus - some water leak and not firing

    HI it is leaking from the ball inside i am afraid you will have to change it.
  3. L

    Loud vibrating noise from boiler

    HI if the noise is coming on ignition then it can many things. 1.combustion door seal loose 2.faulty gas valve 3.soot etc on the burner if the noise is coming after boiler has ignited and it sounds like kettling then BG is right .
  4. L

    buzzing noise from boiler

    HI release water from the system .choose highest point radiator.add chemical in to the system .leave it running normal for few days or weeks if the system is bad. then flush when water is hot.fill water, run, flush with plain water .repeat this few times to make sure all the dirty water has...
  5. L

    Air in loft?

    HI if the system is sealed then the pump should be able to get the air out.i have never had air lock in sealed systems.remember water pressure over 1 bar can easily take the air to the rads where you can release it .why do you need that many air vents ? fit couple if you want but your...
  6. L

    buzzing noise from boiler

    HI it sounds like system is scaled up.was the system ever flushed ? if not try some descaling chemical .
  7. L

    ideal icos 24he

    HI Agile only wants whats right .
  8. L

    full bore isolating valves

    HI bi flow directional .
  9. L

    Recommended Replacement for a T6160 Honeywell Stat

    HI for wireless room stat you need to run mains to the base unit and stat link from the boiler to the base unit.then stat can be fitted any convenient place.
  10. L

    hot water store not heating

    HI what do you mean by bad hot water pressure ?
  11. L

    heatline boiler hot water problem need help

    HI when you open the tap boiler fires .does the flow pipe get hot ?if this happens then it might be diveter valve letting flow out of the boiler .
  12. L

    boiler making bang and vibrating noise

    HI could not upload the soundfile. it could be due to buildup of scale .does it sound like kettle boiling ?
  13. L

    boiler noise - likely nature of problem

    HI could be worn fan.
  14. L

    Air in loft?

    HI is it a sealed system ?
  15. L

    boilers

    HI they are right .most old boilers are fitted in incorrect position.
  16. L

    Combi Potterton Puma 80 mains cut out

    HI it sounds like faulty gas valve.
  17. L

    Biasi 24s cutting out intermittently

    HI i would go for pcb .
  18. L

    buzzing noise from boiler

    HI noise can come from many places.very difficult without more details.
  19. L

    sime super 90 plus - some water leak and not firing

    HI it is very difficult to give advice with info that you have provided.what sort of valve is it ?i doubt that the valve is the cause for the boiler problem. FED UP OF COWBOYS ?TRY INDIANS .
  20. L

    vaillant 828e hot water and heating problems

    HI why did you change the dhw heat ex ??? have you seen filter at the cold inlet valve ?