    hot water tap not running

    HI there is airlock in the pipe.connect a hose pipe to the cold tap and other end to the hot tap.open hot tap fully then open cold tap slowly leave it for 30-50 seconds or until mains pressure pushes air back into the tank .:D
  2. L

    The customer said he has gone off unvented hot water systems

    HI typical of the manufacturers.always blame customers or installers.
  3. L

    Vaillant Boiler Problem - Please Help!

    HI the pin on the gas valve could be or about to be jammed thus leaving the gas valve open all the time.
  4. L

    Megaflo question

    HI it is better to have it on all the time.the stat should keep the water at your desired temp.
  5. L

    Baxi Combi 105 cutting out.

    HI i would also keep HW diaphragm in mind as i have come across this before.HW diaphragm and HW sensor very common on these boilers.
  6. L

    Suprima 60 Boiler Hot water problems

    HI give more clear details on the boiler operation.
  7. L

    broblem with Vailant ecomax 622/2e

    HI need more details of the boiler,the work you carried out and lights that display on the panel.
  8. L

    leaking pressure release valve on old heating system

    HI what is the make ,model of the boiler ? and give more details of the system .we will be glad to help. :D
  9. L

    No hot water (Baxi Combi 105e)

    HI it is located inside the boiler on the bottom front left hand side.diaphragm costs few quid.easy to replace if any experience with the boiler otherwise it can be a nightmare. :D
  10. L

    WORCESTER 9.24 PILOT LIGHT GOING OUT?

    HI pilot assembly needs cleaning.RGI terretory.
  11. L

    vokera synergy 25 e boiler

    HI most likely to be the HW diaphragm
  12. L

    How do i commission my unvented boiler?

    HI you cannot commission unvented system.it is a good system if all well otherwise it can be dangerous.get another qualified engineer.also not all CORGI engineers are allowed to work on it.they need additional qualification for it. FED UP OF COWBOYS ? TRY INDIANS
  13. L

    No hot water (Baxi Combi 105e)

    HI does the boiler come on in CH mode ?
  14. L

    tap washers - different sizes for same taps!?

    HI there are many different types of washers.if you are not sure take the tap gear to the shop and get the one that fits.
  15. L

    Lead to Copper pipe

    HI buy a fitting which is called LEADLOCK .use it to connect lead to a copper. then fit stoptap to copper .i will explain again. old lead to LEADLOCK fitting LEADLOCK fitting to new 22mm-15mm copper copper to stoptap happydays :D
  16. L

    sink and bath waste

    HI what external pipe ?need more details.
  17. L

    Wall mounted combi under an electric hob?

    HI why are you doing this ? 1.people spend money to move boiler from the floor to the wall and you want opposite 2.it is bad idea to install the boiler under the worktop specially if it is wall mounted combi boiler. 3.worst place for a boiler
  18. L

    Draining a boiler

    HI sorry but i think you will struggle if you do not know how to drain the boiler. 1.turn off boiler at mains 2.turn off water at mains 3.release water from drain valve or any ch/boiler drain point. 4.open hot taps 5.rock and roll
  19. L

    central heating pump runs all day!!??

    HI what is the make of the boiler ?
  20. L

    system boiler in bedroom or bathroom?

    HI i prefer the boiler in the bathroom.most people cannot sleep when the boiler is running in the bedroom.