  1. past3bar

    Glow Worm ultracom 38cxi heating

    I would think the most knowledgeable people to speak to would be glow worms technical help department. You will find the number in the service and installation manual which you should of had in your possession for about a week.
  2. past3bar

    KETTLING?

    It's the hot water heat exchanger.
  3. past3bar

    1st floor rads not working

    If you have a cylinder to heat hot water is the system controlled by a 2 or 3 port valve and did you make sure this was manually open before and during filling? Make doubly sure the radiator valves are open at both ends of each rad. It sounds like you may have got air or dirt trapped in the...
  4. past3bar

    randal fp715si

    See you are obviously a computer whizz!
  5. past3bar

    Rusty Towel Radiators

    It is more important that your system is cleaned out properly on any installation of radiators, boiler etc. It is also important that a corrosion inhibitor is added and maintained at the correct concentration for the volume of your system. This can take time and cost money and is usually one...
  6. past3bar

    randal fp715si

    Ring Danfoss in the morning. Their tech help are good. 01234 364621 or the manufacturer of your new programmer. (china may be pricey call though)
  7. past3bar

    Worcester 24i boiler not lighting!

    Sounds like flame rectification or gas valve problem. You need a registered gas installer to look at it.
  8. past3bar

    KETTLING?

    You have a separate calorifier for hot water on that model . You probably need a Registered gas installer to check your burner pressure in DHW mode
  9. past3bar

    1st floor rads not working

    Do you have separate controllers on each floor i.e. roomstats? Do you have water in the F&E tank? Have you tried shutting all other rads down on other floors to see if the heated water pushes through?
  10. past3bar

    Chaffoteaux 80 se Help Please

    Probably full of LS-X where someone has previously tried to stop the lip seals leaking.
  11. past3bar

    C & M Brittony boiler hot water problem.

    Shatt use the name Britony for more than one boiler. Do you have any more information on model? From what you wrote it sounds like a later SE ? flow switch?
  12. past3bar

    Overheat stat for Radiation fuelsaver 15rs

    Have you tried the obvious nationals like Parts Centre (refuse to spell it the American way), Curzon etc? Internet search? Google 'Federation of Heating Spares Stockists' . I'm sure yoiu will be able to track down a helpful independent.
  13. past3bar

    sludging up of double rads

    News to me if true. There are certain remedial procedures and preventetive measures that can be undertaken to reduce or even eliminate sludge in most systems.
  14. past3bar

    Copper pipes in concrete

    I thought Denso tape was designed to make your hands go rusty.
  15. past3bar

    Worcester Junior 28i, hot water is fine, but CH stopped...

    Get someone competent to by-pass your stat. Will only take a few minutes then you will be able to rule it in or out. Is it just a digital stat or programmable stat. Do you have a separate anologue clock on the boiler for instance. Is the little pin/lever corresponding with the call i.e. constant...
  16. past3bar

    Radiator Cold Goes Hot When Bled Then Cold Again

    I would try opening both lockshield and TRV fully. I would then shut down all other rads on system. If I still didn't get heat flowing through I would drain and check that my valves were not stuck. I know you have done this but do it again and tap the TRV with a spanner. If you are fairly...
  17. past3bar

    WB Greenstar 28i junior - Water down Flue ?

    There is a electrical connection at the back of the gas valve which is almost in the bottom of the casing on older models. This connection is prone to getting wet if excessive water enters the flue or the angle of the flue is too much. If the the connnectors subsequently get damp the cause a...
  18. past3bar

    Baxi Solo 2 PF clicking noises

    Dont buy a pcb till you have checked the integrity of the plastic sensing tubes to APS. These are a lot less than a pcb and tend to crack or disintegrate. a word of warning though, be careful when re-fitting to the metal tubes which run up the back of the boiler as you can easily lose one in the...
  19. past3bar

    baxi 105e

    ? No. Just T into boiler return as near to pump as possible. I use a flexi connector and never have a problem.
  20. past3bar

    Type of radiators to pick?

    The only problems with the 'centerbrand' rads is that the vent plug sometimes snap off if overtightened and it's difficult to add chemicals. The myson brackets can be a bit of a pain. Stelrads and Henrads are easy.