  1. R

    WEEE Charges

    Its highly likely that they have joined a WEEE complanace scheme. They must "declare" the ammount of WEEE they put ount onto the market per annum and are charged depending upon that amount. The fee for the lamp will be an add on cost to cover them for there loss.
  2. R

    Is the way this gas bonding is being done correct?

    Where practicle Gas bonding should be done within 600mm of the meter OUTLET not before the gas pipe enters the meter. Or at the point of entry of the service to the house if the meter is external
  3. R

    Second opinion wanted

    Tell the spark that your wife will pay him in kind. Tell your wife that if she wants a holiday then............. :D
  4. R

    Wiring up an Oven

    Yeah true enough Crafty, Guess its up to the OP then
  5. R

    Wiring up an Oven

    Too Right but if the manuals says put it on its own circuit then it may invalidate the warranty, they will use anything these days to get out of coughing up.
  6. R

    Wiring up an Oven

    ok so you oven has a rating of just over 9.5A so its fine on 1.5 cable (so long as the run is not too long) but to be honest you really should put in larger cable for future preference if you can afford to. No you definatly cannot put this on the ring main cct as the 30A fuse will not protect...
  7. R

    Hiding Plasma TV cables...

    You could always try spiral wrap for (a bit) of protection, not a good as conduit but saves you hacking the ends off http://www.tlc-direct.co.uk/Main_Index/Cable_Accessories_Index/Cable_Tidy/index.html
  8. R

    Extending a master phone socket

    http://www.tlc-direct.co.uk/Products/GPJB.html use one of them then to extend your incoming cable. Not sure if its your property or BTs property mind!
  9. R

    Extending a master phone socket

    You can buy telephone extansion cables everywhere, they probabably do them in the £ shop Heres one from..... http://www.argos.co.uk/webapp/wcs/stores/servlet/ProductDisplay?storeId=10001&langId=-1&catalogId=1500000701&productId=1500040811
  10. R

    Picture of the week!™

    Whats going on with the earth under the fuse carrier it dissapears into the backbaord?
  11. R

    NAPIT Inspection, testing circuits and awkward fusebox??

    Mike I was actually meaning build the board to improve your inspection and testing skills, I dont think your examiner will except you showing him a practice board for your assesment. What these guys want is for you to show them something you have installed previously, they will ask you...
  12. R

    NAPIT Inspection, testing circuits and awkward fusebox??

    Make a fake board: Get a piece of MDF bout 1.5mx1.5m Stick on a CU (with RCD), Put a ring circuit on it, A radial, A two way lighting circuit, 2 pipes to simulate Gas and Water (connect up your bonding). Wire the cu with a 3 pin plug on it so you can do your live tests and there you go you...
  13. R

    NAPIT Inspection, testing circuits and awkward fusebox??

    How much testing have you done Mike? you should be able to demonstrate that you can PIR the installation. I see your point about it being old but so what the tests dont differ any (with the exception of an RCD)
  14. R

    NAPIT Inspection, testing circuits and awkward fusebox??

    I dont know what your asking here, Are you saying you cant change the CU beacuse you cant safely isolate it i.e (scared cutting the tags and pulling the fuse etc)?
  15. R

    PS3 US Plug

    Have you actually tried this or have you just picked up this information from the internet ? I only ask as when I worked at the cable manufacturers we made all sorts of cables even those for games consoles. Once a numpty from the waherhose decided to sneak into my office when I was on holiday...
  16. R

    PS3 US Plug

    I have an imported Jap PS3 game "RR7" and it doesnt work in a UK console. Like I say the early model PS3 cosoles were region free for blue-ray Discs maybe they just decided to keep making them regioin free.
  17. R

    Now scared of prosecution

    Oh you will be taking about the Part P regs that came into play in Jan 2005 not the actual Brown bible of electrical regulations, sorry my bad should have realised. Yeah Part P Kitchens and bathrooms and other bits the DIYER cant do in the home. Yeah that is a legal thing and your going to Jail...
  18. R

    Now scared of prosecution

    Dont worry the regulations are non startory however the regulations may be used in a court of law in evidence to claim compliance with a statutory requirement. anyany if you call a spark in to put it right do you honestly think he will grass you up. To Who???? You are doing him a favour by...
  19. R

    Wiring in a partition wall

    correct Safe zone any depth... Not in safe zone >50mm I suppose if yor plaster board is 12mm either side then in theory you have 24mm in the middle to lay your cable. if its 9mm then....Youve guessed it. You can also put a cable where you like (outside safe zone at whatever depth) if its...
  20. R

    PS3 US Plug

    You will probabelyneed an Auto Transformer of the correct VA read the back of the console it should say something like 110V 3.8A 50/60HZ think thats the spec for the US PS3 Why has he bought a US console he will only be able to play imported NTSC games and Region 1 DVDs and Region A/1...