  1. Crofton Gas

    Flushing central heating system question

    The black sludge is iron oxide, known as magnetite, which is a result of the water in the system oxidising and breaking down the inside of rads, its then magnetised as it passes through the AC field in the pump and sticks together. Inhibitor only slows this process and does not stop it. A...
  2. Crofton Gas

    Do I need 'boiler plus' controls? Advice please

    As it's a Combi you will need to comply, which boiler have you been quoted for?
  3. Crofton Gas

    heating stuck on in heatwave!

    Its more than likely one of the motorised valves internal switches
  4. Crofton Gas

    Trumpet noise coming from water system

    You need to use an unvented qualified plumber to work on that cylinder
  5. Crofton Gas

    Roughing out Bathroom plumbing

    Take the easiest pipe route, whichever that is, making sure you have access to the fittings. The bath and sink can be combined internally, you don't necessarily need to go up to 50mm, as it's unlikey the bath and basin would be drained together, swept 40mm tee with 32mm reducer from basin
  6. Crofton Gas

    Noisy toilet flush in the morning

    Replace diaphragm washer, it's probably stretched
  7. Crofton Gas

    Is this waste connection unusual or wrong?

    Yeah, that's a boss fitting
  8. Crofton Gas

    Advice needed on the correct size of boiler and gas supply pipe please

    Definitely go with Vaillant, depending on gas pipe run, you could get a EcoTEC Plus 412 12kW, which should be suitable for the size of your property. An additional energy saving device is required under boiler plus for Combi, for regular boiler it must have a timeclock and room thermostat to comply.
  9. Crofton Gas

    Preparing copper prior to solder

    Flux has a cleaner in which is activated by heat, so oxidised pipe is fine, as long as it's not old or dirty. Most plumbers will use a pipeslice which leaves minimal burrs anyway
  10. Crofton Gas

    Constant running overflow problem

    Your system is unvented, which is why you don't have a tank, often when the valve let's by, it wont reseat. You need to get an unvented qualified engineer to work on this system. The red handle valve is a pressure relief valve PRV which is a safety device. The whole caleffi block doesn't need...
  11. Crofton Gas

    Please help read electric dial meter

    09804 10163
  12. Crofton Gas

    What's this part called and should the black bit be tight?

    Auto Air Valves are for filling/commissioning only and once the air is out the system the black cap is shut to prevent leaks
  13. Crofton Gas

    What's this part called and should the black bit be tight?

    Automatic Air Valve and black cap should be shut.
  14. Crofton Gas

    Swapping Honeywell programmer and thermostat for a Nest gen3

    Yes, you will need to replace the programmer with a heat link.
  15. Crofton Gas

    Installed Tado and radiators are not turning off

    Photo of tado wiring would help...
  16. Crofton Gas

    New thermostat not turning ventral heating OFF

    Sorry response was vague, Brown to live Blue to neutral Black to 4 Link wire from live to 3 common
  17. Crofton Gas

    New thermostat not turning ventral heating OFF

    Live should go to terminal 3 not 4...
  18. Crofton Gas

    Central heating pump short overrun

    If you have a multimeter it's worth checking the voltage on the Orange wire from the 3port actuator, when the thermostat is satisfied there will be no voltage on the Orange, Keep multimeter on and see if you get 240v when the pump starts again.