Search results

  1. P

    Vaillant Ecotec 831 rubber hose

    we deal with these boilers everyday,i would change these legs because if they split it can take out fan and pcb due to water damage.You have done the hard part by taking legs off,£75 is cheaper than a pcb and fan :wink:
  2. P

    vallant ecotech 824 boiler leaking

    these do have problems with these boilers,leaking legs and pressure sensors go out on f75 but better than worcester , biasi ideal and all the cheaper models.
  3. P

    peugeot partner

    hi i have been to 5 different suppliers and they all come out with the same one
  4. P

    peugeot partner

    hi all i have a 1.9d van and had aleak on rocker cover,ordered gasket and took off cover.The trouble is the gasket seems to fit in a groove but my cover and head are both flat so no groove.is there any over gasket to fit.I have done a temp fix with a liquid gasket but not working very good.Any...
  5. P

    chrysler voyager mechanic

    hi all i am trying to find a chrysler mechanic to look after my voyager 2.8 d 05 plate.I want to avoid main agent who tried to charge me £150 per hour ,not a bad living.thanks i am in essex around romford area but i can travel thanks peter
  6. P

    hi kirk was interested in the plans of w,y and s plans that you have if you get time would you...

    hi kirk was interested in the plans of w,y and s plans that you have if you get time would you be able to forward them on thanks peter
  7. P

    Potterton Combi 80 Central Heating Issue

    hi the best way to test diverter valve is to turn off boiler and let it cool down,once it is cool,turn on and run hot tap straight away.Whilst the hot water is running feel the 22mm pipe that is on your right as you look at the boiler.If this starts to get hot then your diverter is letting by peter
  8. P

    Drayton Digistat RF1 and Greenstar 28i junior- ODDNESS!!

    let me know how you get on i will look in my van may have spare one
  9. P

    Drayton Digistat RF1 and Greenstar 28i junior- ODDNESS!!

    we fit alot of these room stats and the recievers do fail alot.a easy way around it as a temp repair is to turn off power undo reciever and join wires 1 and 3 you can put them in to number 4 on reciever this will do away with room stat and you can work the boiler on its own stat.you will have to...
  10. P

    sabre he 35 combi boiler problem

    check pressure gauge make sure it reads aleast 1 bar if not top up system via filling loop
  11. P

    jeep grand cherokee td

    hi i have trouble starting it.Once started i can start it every day no problems but if i leave it a week i have to crank it for a long time and most times till battery is dead.I have changed glow plugs. It almost as if the fuel has drained out of engine and takes a age to get it back to the...
  12. P

    Vailliant Combi Boiler Problems

    hi common fault on these the diverter has gone .Rubber has gone and does not let arm make on micro switch
  13. P

    biasi prava combi

    posted in cc if that helps
  14. P

    biasi prava combi

    hi have a problem with a boiler i went to today and i am not that clued up on these so some help would be great.The boilers fires up and runs for about 10 secs then stops,it then relights.It keeps doing this but does not go to lock out.It has the same fault on dhw and ch.No fault lights show.Any...
  15. P

    Chaffoteaux 80 se Help Please

    most likley that the plate to plate heat exchanger is blocked ,common fault with the se.
  16. P

    elson coral e

    Thanks seco for that,horrible units these.Thank you once again pete
  17. P

    elson coral e

    it gets off of temp but as soon as you run hot tap it runs warm for 10 seconds then goes cold thanks pete
  18. P

    elson coral e

    Been called to this unit today.No hot water was the fault.After speaking to Elson they suggested to change the blending valve,but no difference.The sysyem is fully pressurised with abaxi solo 3 providing heat.Flow from boiler is hot and return hot.Both pumps have been recently changed.Could...
  19. P

    grand cherokee 3.1td

    Tested the amount of time there is power to the plugs and that is 25 sec.Have tested the ohms all very low readings ,any other ideas thanks peter
  20. P

    grand cherokee 3.1td

    thanks for the reply how long should they stay on for.
Back