  1. Bonding of Gas Meter

    Bonding of Gas Meter

  2. L

    CFL abuse

    May the light shine upon you - even if it is energy saving! :D
  3. L

    shaver socket

    Yes it's ok to take it from the lighting circuit but remember all work in a bathroom comes under Part P and you know what that means, don't you?
  4. L

    down lighters MDF??

    You might be better off using these
  5. L

    double switch to single dimmer

    Hi Martyn At the moment you have two single switches, so you need to join the two commons together from the separate switches to the common of the dimmer. Now if one of the commons has a link to the other common then just use the one wire and you won’t then need the link wire. The two other...
  6. L

    fuse box

    If that is the right fuse for the shower circuit. But the fuse will only be 30A which is hardly sufficient for an electric shower.
  7. L

    Same Guy?

    He made it look all soo easy.
  8. L

    dim flouresants

    Can you try swapping one with another somewhere else that you know works? That way you'll know if it's the fitting that's faulty or its location that's a problem.
  9. L

    Leave shower pullcord on or off?

    Sure it hasn't sent you blind :lol: :lol: :lol:
  10. L

    Invention please

  11. L

    Sockets in Lath and Plaster Wall

    Don't see why not, as long as it's not going to compromise the strength of the stud.
  12. L

    HELP ........... can i do this work legally

    I agree it is very confusing, not exactly black and white. But AFAIK it's not so much whether you're qualified but whether you're competent. So, you could be qualified but not competent. Alternatively, you could be competent but not qualified. Clear?
  13. L

    HELP ........... can i do this work legally

    You don't have to be registered with nic as Part P only applies to domestic work. Of course your work still comes under 17th regs. So from what you say you'll more than likely only need to issue a MWC.
  14. L

    Calling all Sparks...

    No doubt if it was a gas man calling to replace your boiler you'd happily pay £2000-£3000 without a quibble!
  15. L

    Putting a switch on a 12v battery

    You could use something like this switch somewhere accessible between the battery terminals and the lamp.
  16. L

    oven cable size.....??

    Your cooker circuit terminates at a cooker control unit which should be situated where it is easily accessible, and not above the cooker. You then need to go from there to a cooker connection unit using your 10mm² cable. From the cooker connection unit you will attach yor cable to the cooker...
  17. L

    oven cable size.....??

    After taking diversity into consideration I would have thought 10mm² very adequate.
  18. L

    Voltage on Central Heating Pipes

    Bonding will go from your mains water stop cock and within 600mm of your gas meter (assuming you have GCH) to your MET (main earth terminal). What type of supply do you have? Can you send in a pic of the supply intake?
  19. L

    Cable from master box - old colours (phones)

    AFAIK you can't. BT has to come and fit a master socket from where you can then run your extensions if you want to. Up to master socket belongs to BT, after it is your responsibity.
  20. L

    cable/kw

    As we now come under 17th edition of the wiring regs any cable now virtually has to be RCD protected. Good practice under 16th ed as well. As to what size will depend on various rating factors, not least is if it will be enclosed in insulation. As general rule of thumb, most electricians...