Search results

  1. B

    Skim over previously tiled wall.

    Just removed the tiles from the walls in a bathroom. Dont want to fully tile all 4 walls now so hope to get the room plastered over. Is there any worry with plastering over the tile adhesive remnants on the wall or have i got to spend hours and hours chipping it all off? Ta in advance.
  2. B

    Hairline cracks to ceilings and walls

    But is the product any good??? Whats the Wiko one called??
  3. B

    House for sale - What extension / building allowed

    Will they provide all the information to anyone then about any property? Do they charge for such information?
  4. B

    House for sale - What extension / building allowed

    How can you find out what limitations are implimented on buildings / houses for sale? We have seen a small holding we are led to believe has very limited building permission available due to green belt / agricultural building and occupier limitations. but how can we fid out.... Seller is...
  5. B

    WC fitting - waste in the floor query

    Thanks mysteryman. Maybe worth a look about then to see if any available over here.
  6. B

    WC fitting - waste in the floor query

    Its a clay pipe dropping thru a concrete floor. I had worked out moving the wall forward was an obvious get around but was looking for a eureka moment from someone in the know... thought there may be a toilet for this sort of installation? Maybe not then?
  7. B

    WC fitting - waste in the floor query

    I have just removed my bathroom for refit. I have found that the WC waste is through the floor with its centre 9 inches from the wall. Will any standard wc be able to fit this situation? Do i need to sorce a certain type of WC to suit? Was buying a new suite tomorrow but want to be sure...
  8. B

    Glow worm compact 100e - DHW probs / part no advice plse

    What a pain of a job.. Removed the conversion kit pipework for top connection, but the p heat exchanger wouldnt come out. Had to take the whole pump assembly and block out as there had unknown to me been a slight leak there and the heat exchanger was well and truly stuck to the block... Long...
  9. B

    Glow worm compact 100e - DHW probs / part no advice plse

    Thanks for that... Did a quick search before but didnt see the part numbers.... if i cant find i will call Glow worm on monday?? Will go further back in the searches.... Put some flushing agent in the system this week and its helped a bit... just moved the muck probably! What about recon...
  10. B

    Glow worm compact 100e - DHW probs / part no advice plse

    Hi, Had a similar problem before which was down to the Plate heat exchanger being partially blocked. On DHW mode water goes hot/cold/hot/cold (and trips now and then) as burner goes on and off. I assume on the primary stat temp control?? On shut off of DHW some kettleing can be heard and...
  11. B

    Glow worm Compact 100e- New DHW micro sw retaining clip rqd

    Ta for that, The gland is not leaking now. Will keep a check on it though and replace the gland should it do so.
  12. B

    Glow worm Compact 100e- New DHW micro sw retaining clip rqd

    Due to the old retaining clip corroding and no longer holding the DHW micro switch in place properly my boiler has been calling for dhw when not required. The switch works ok but the sprung steel retainer is now dust?? I assume a minor leak in the area of the pin that operates said micro sw...
  13. B

    Baxi 105e - Luke warm DHW continues....

    The kitchen tap does have a large flow rate similar to a bath tap.... Bath tap... same problem. I will check the flow rate.
  14. B

    Baxi 105e - Luke warm DHW continues....

    No. I thought about the divertor valve and isolated the ch system via the valves at the boiler flow and return. DHW still does same.... However since last post i have noted that the boiler gets up to temp when dhw flow is reduced and the as a result the dhw temp increases.... However it used...
  15. B

    Baxi 105e - Luke warm DHW continues....

    The Dhw on my Baxi 105e isnt getting as hot as it used too. Having posted on here previously on the same issue i have followed the advice and changed the dhw temp sensor and the plate heat exchanger after flushing the system out. All to no avail. When running on c/h the water temp indicated...
  16. B

    Baxi 105e - luke warm DHW

    Going for the flush out, change the thermistor (dhw temp sensor) and the plate heat exchanger. Fingers crossed that should sort it out.
  17. B

    Baxi 105e - luke warm DHW

    Blimey.... Heat exchanger is only £48! was expecting another £100 on that. Re the thermostat... sorry meant temp sensor/thermistor. Might change it at same time as its only a tenner. Re. Would that be primary or secondary??? The plate heat is sometimes incorrectly referred to as the...
  18. B

    Baxi 105e - luke warm DHW

    Thanks Baxipoti. Would that be primary or secondary??? Best way to clean it if its the secondary (dhw side) ??? Can it be removed and soaked in descaler? On another forum i was told dhw thermostat??
  19. B

    Baxi 105e - luke warm DHW

    Anyone..... please :)