  1. DHFrames

    UPVC sash window fixing issue with brackets

    The lugs should be designed to clip on, the 50mm overhangs the front of the sash and needs to be bent at a right angle so you can then fix into the stone work. Personally never used lugs on sash, we always screw timber around the sash, gives us something to pin the timber architraves to. A God...
  2. DHFrames

    Undoing window restrictor

    Its called building regs.
  3. DHFrames

    How to adjust UPVC butt hinge

    Pic 5, turn the screw and the hinge should move the door. If the door is catching at the bottom, need to send the bottom of the door away from the hinge and the top towards the hinge. May have to re pack the glass/panel (toe and heel)
  4. DHFrames

    French doors installed too low?

    Trickle vents on a knock through? Its not technically a new opening is it? I don't fit them on a knock through. Also I quite often go below DPC on a knock through to give the lowest possible threshold. I wrap a new dpc down and round although Ive always considered this over kill as the PVC...
  5. DHFrames

    best upvc adhesive

    We use glue and activator for all trims, double sided tape works as well. Depending on the gap once the sill has been levelled, either silicone or foam
  6. DHFrames

    French doors installed too low?

    Looks to be welded in one Gaz, top right I think you can just make the weld out viewed inside. The fitter is clutching at straws if if thinks he'll replace the side screens, will look naff as well This install needs to go though LABC to be signed off, depending what inspector you get, if it's...
  7. DHFrames

    Bi fold door,

    Can go upto 1200mm per pane on ALuk, I'd go for 3 pane, better sight lines, the door can then fold round onto the other doors instead of being hinged on the wall side which is your only traffic door option on a 4 pane
  8. DHFrames

    Deceuninck Heritage 2800 or Eurocell Modus

    Never used Eurocell for the Flush system so not sure on prices. Front of a house from CWG is approx £2000-2500 X2 3 seg bays and a single window
  9. DHFrames

    Deceuninck Heritage 2800 or Eurocell Modus

    Try CWG Choices for flush 70
  10. DHFrames

    uPVC Window Spare Part

    If there are any remaining pieces of the block left in the window simply pull them out, or use a screwdriver to bend them out
  11. DHFrames

    uPVC Window Spare Part

    Does the window catch when you close it? If so its hasn't been "toe n heeled" correctly If the window works fine then leave it
  12. DHFrames

    uPVC Window Spare Part

    Save your money, they serve no purpose apart from guiding the window in. Most installers remove as in time they only catch. If the vent has been packed correctly it won't be needed
  13. DHFrames

    Replacement 'J' Shaped Bay Window - Double Glazing

    The 15mm discrepancy is where they deduct the bay pole from the overall measurement. 530 is from the weld of the sill to end of the window
  14. DHFrames

    Replacement 'J' Shaped Bay Window - Double Glazing

    The surveyor has replicated the existing sizes presuming they are correct. Looks like the old bay was 100mm short on the end window, the surveyor has presumed the trims are there for a reason and gone with the same width, when the trims really should of been removed. It's not correct, the...
  15. DHFrames

    Replacement 'J' Shaped Bay Window - Double Glazing

    Looks like the end window has been made 100mm too short or the angles on the welded sill are wrong Demand it to be put right Hopefully you haven't paid in full Pictures are poor, can you upload some more
  16. DHFrames

    UPVC Window Specification Advice

    God is your way, he's your man
  17. DHFrames

    UPVC Windows - Who to Avoid?

    Where are you based? Pm your details, we'd be happy to quote for you. Good to always get a few quotes from local companies. Look for double glazing companies near you on here http://www.freeindex.co.uk
  18. DHFrames

    New uPVC windows scratched - repair or replace?

    Same price Gaz to have it sprayed in the factory or on site. No risk of damage if sprayed after installation. We've had windows sprayed before in the factory, this is the way forward for us now. Existing timber window replaced with our UPVC window
  19. DHFrames

    Double glazing company certs etc

    Was there a contract including payment plan? Are the company Fensa or Certass registered? All installations should be certified within a month of the install date. (2 weeks for Fensa) Windows being fitted 18 months ago and still not signed off tells me they are not Fensa reg. Start asking...