  1. T

    salamander pump pulsing

    It is easy to remove, turn off water to both hot and cold, undo large nuts at back of valve holding valve to the wall. look into the back of the connections in the valve and the nrv's should be there see link below...
  2. T

    Dripping Tap In Kitchen

    So many company's are now importing these taps now to maximize profits. Most major UK brands are import taps so really the only benefit of buying a UK brand is the guarantee and spares.
  3. T

    Dripping Tap In Kitchen

    There are lots of good import taps around that are cheap but its getting the spares in four years time that is the issue I just googgled Lamona and it is not coming up with a UK based manufacturers web site.
  4. T

    Dripping Tap In Kitchen

    If you mean to replace your tap I would not use there over priced import own brand rubbish, go to a merchant and use a UK based branded tap else you will be making the same mistake again. I have used lots of these cheap Bristan taps and they have been reliable and you will always get spares...
  5. T

    salamander pump pulsing

    Remove the non return valves from back of the valve, then try it. if that solves the issue try putting in inline nrv's that need less pressure to open them you can fit these any where between the pump and the shower valve.
  6. T

    Dripping Tap In Kitchen

    If that is a two handled mixer I have not seen one with a plastic valve for a long time, they are normally plastic on single lever mixers with a square spline, you have got to either replace the tap, or know the manufacturer to get a spare cold valve now that you have broken the spline.
  7. T

    hot water going cold

    You might be getting air in the pump on the hot side of the pump which will lower the pressure if its a centrifugal pump, making it hard for the valve to mix with the cold side as this side will have a higher pressure. The inlet valve on your WC might need a new washer they can distort or...
  8. T

    hot water going cold

    Turn off the pump electrics and see if the temperature comes back to normal levels, if there is a handset and hose then remove the handset and lower the hose for a couple of minutes then try shower again. I have a feeling that your hot water is stored too high in temperature.
  9. T

    Shower Pump

    Richard C, has pointed out two important points too you never fit nrv's before pump, do not install pump too far from the cylinder. 2 meters for a 22mm pump 3 for a 15mm but the closer the better. Supply pipes to pump should also be independent for pump. What model is it?
  10. T

    gebrit duo fix frame

    The Idea of the square flush plates is that you can service them all from the front. So boxing in is fine.
  11. T

    hot water going cold

    With out going all high tech simply with your hand will do, pipe on the left as you are facing the shower should be hot, if the temprature cools on this pipe when the shower cools then its not the valve. Is the shower pumped?
  12. T

    Crosswater shower valve only producing tepid water

    I know mate but it does not mean there is even pressure on both sides. Salamanders are notorious for air in impellors and loosing pressure on the hot side of the pump.
  13. T

    Crosswater shower valve only producing tepid water

    I do not think it is the valve else the valve would not get hot when a cold tap was turned on. Crosswater have only used two thermostats in there valve the latest one that has been around for 18 mounths and the old IB one that they use prior to that one. I suspect that you are using a...
  14. T

    Google Chrome

    It does not you are right, But I do not go on any other forums.
  15. T

    showerforce easiboost shower pump problem..

    With The easiboost the bigger the pump the noisier, they are all fairly noisy unless you go for a 22mm pump they are quieter but replumbing required. If you went for the 2.0bar It would be the same with the hoses but the pump runs faster on that one to create the extra pressure so it would be...
  16. T

    showerforce easiboost shower pump problem..

    The showerforce easy boost was a 15 min on 60 min off pump that means that if you used it for more that 15 mins then it would cut off for 60 mins then work fine. If your hot water temp has not gone up and exceeded 65 degrees, then you unfortunatly need a new pump. they are not manufactured...
  17. T

    Google Chrome

    I have now uninstalled Chrome as it was trying to take over lots of my settings like changing my home page in IE7 to Google side bars popping up even when I was not online. :( Thanks for the feed back Guys. I should have known better. :roll:
  18. T

    CT50 problems

    If you plumb in anti gravity Loop as Seco Mentioned this should do the trick, use a techflange they are less likly to encourage air pre anti-gravity loop. It will make all the difference if you fit it on the floor of the airing cupboard you would also not need the Techflange or the anti...
  19. T

    shower pump problem

    ST Pumps do not have a temperature sensor. Yes you should have bought a twin pump. or two singles. You might not have enough flow when trying too mix the water together, Turn off pump at electrical switch, Get a bucket, run shower till hot, turn shower control full hot, measure flow (place...
  20. T

    Google Chrome

    Thats it I am going to burn my PC and cut the cables. And change my password from technotim on all my bank accounts and all my logins swap my pin 1024 on my debit cards and all my logins.