    Vaillant ecomax pro 18e condensing boiler

    F1 is ignition lockout if an airlock or over heat situation then F5 will show as there is no mention of F5 only F1 the boiler normally has 3 attempts at ignition then defaults if you cannot reset boiler sounds like a pcb fault and will be covered on warranty.
  2. G

    Flat expansion vessel

    The flexi hose to the exp. vess. block on this boiler giving the same fault as a faulty exp. vess.Normally you can pump the vess. back up to 1 bar they rarely need replacing.On the odd occassion i have replaced them it normally takes 2 hours,3 hours max if in a difficult position.
  3. G

    Pilot light always on?

    I think you have a MK111 boiler if so the pilot lights when calling for heat and will stay on untill switched live is off. Have you turned the power off or just the boiler stat could be ext. valve sticking sending power to boiler,also there is a jumper on the p.c.b which s/be removed not sure if...
  4. G

    Jaguar Boiler 24

    Had similar fault was the cvi unit would light but not rectify
  5. G

    Glow Worm Boiler - Water Leak

    If it is the seal on the flue adaptor it should be covered as a warranty job by glow-worm as it is a manufactured fault.It will need to be addressed as the codensate is acidic and will rot any copper or steel it comes into contact with.
  6. G

    Glow worm pressure loss

    A very common fault on this boiler is the flexi exp. tube blocking preventing the exp. vess. from working gives the same symptom of failed exp. vess.It has been mentioned numerous times on this forum and should be checked.
  7. G

    Glow Worm microturbo 40

    If it is a micron and has green lights but are not flashing a fault sequance check the flow and return temp sounds like it is over heating the 30-50 has not got pump o/run.If system or h/exch flow restricted on shut down boiler will go above 95deg and go to lock out
  8. G

    Glow worm 24ci only produces warm water

    Before you change any parts check the gas working pressure and burner pressure.Had a similar prob. turned out to be faulty governor on the meter.Found it on third visit previous visits all ok.Transco turned up as i was leaving said no fault, yet only 10mb when i checked it got them to change...
  9. G

    Gloworm Compact 75

    Could be a faulty flow sensor
  10. G

    glowworm 30ci

    Have come across this many times a local council used an installer who either did not flush or clean syst. properly result the divertor valve would spin usually in dhw mode.Changing the divertor cartridge will fix, but may only be short term agood flush will help at same time.Also to much...
  11. G

    GW Micron 50

    Sounds like you are describimg the o/heat cut out the thermister is just pushed into a phial pockeT a long copper sensor in two halves on the older one the new is one piece. As the boiler has not got pump over run tend to find a few that have overheated and need to be reset.
  12. G

    Glow-worm Energysaver Combi 2 100

    Have worked on two these in the past both not letting c/h work but different faults.First was the dhw store thermistor faulty.Second was known as dripping tap syndrome(COMMON ON THESE BOILERS)the boiler senses dhw movement and so prevents c/h from coming on.Either turn off dhw on boiler, or...
  13. G

    Gloworm 30si boiler

    Just remembered the flexi-tube to the exp. vess. block on these to and gives the same symptom of a faulty exp. vess.
  14. G

    Glowworm Compact

    The compact with the hall effect sensor is the P range it has a bi-thermal h/exch (no plateh/exch) and a pilot, can be difficult to change sensor from memory.
  15. G

    Gloworm 30si boiler

    The SI range has not got a filling loop built in it will flash red because of low water i would check the prv and expansion vessel pressure
  16. G

    expansion vessel

    Eggy it may not be the exp. vess the flei tube to the boiler can get blocked causing the same symptom as a faulty exp. vess You may need to change the prv as they get muck on the seating when they lift and can letby especially if you keep refilling the syst. with un traeted water
  17. G

    expansion vessel

    Eggy it may not be the exp. vess the flei tube to the boiler can get blocked causing the same symptom as a faulty exp. vess You may need to change the prv as they get muck on the seating when they lift and can letby especially if you keep refilling the syst. with un traeted water
  18. G

    Gloworm extrafast 96 boiler

    Could be the wiring harness( if the pressure switch is sound) giving a misleading fault
  19. G

    Micron 60FF Reset Problem

    Check the pump is wired correctly and the water is ciculating round the system.When the boiler reaches temp the pump should run on if it does not the latent heat rise can lock out the boiler this is fairly common on the 30/50 which does not have a pump over-run.Another poss. is the o/heat stat...
  20. G

    Gloworm EnergySaver 50e Condenser Boiler

    Cleaning/removing the injector is corgi territory you should not attempt this as you prob. do not posses the knowledge or equipment to test for gas leaks on re-assembly the burner is water cooled by the way so the system would need draining to remove this