  1. G

    Gloworm EnergySaver 50e Condenser Boiler

    Cleaning/removing the injector is corgi territory you should not attempt this as you prob. do not posses the knowledge or equipment to test for gas leaks on re-assembly the burner is water cooled by the way so the system would need draining to remove this
  2. G

    Gloworm EnergySaver 50e Condenser Boiler

    The gas enters the burner via the injector situated on the left hand side the electrde will need to be replaced if you cannot unscrew it it may need a new burner assy.By the time you have employed a corgi reg engineer and costed the replacement part it would probably be better to replace the...
  3. G

    Glow Worm Compact 75p combi

    The pump does not run during dhw mode it has a bi-thermal h/exch and relies on mains pressure to lift a flow sensor.The pump may kick in when hot water is finished to dissipate the heat out of h/exch.The pump needs to run in c/h mode.The problem mentioned could be many faults the engineer s/be...
  4. G

    Glow Worm Compact 75p combi

    The pump does not run during dhw mode it has a bi-thermal h/exch and relies on mains pressure to lift a flow sensor.The pump may kick in when hot water is finished to dissipate the heat out of h/exch.The pump needs to run in c/h mode.The problem mentioned could be many faults the engineer s/be...
  5. G

    Micron 60FF Reset Problem

    It normally means it has over heated i take it the pump is wired to the boiler pump over-run terminal On the pcb the reset and burner lights flash in different sequances denoting possible faults.
  6. G

    Micron 60FF Reset Problem

    It normally means it has over heated i take it the pump is wired to the boiler pump over-run terminal On the pcb the reset and burner lights flash in different sequances denoting possible faults.
  7. G

    Micron 60FF Reset Problem

    It normally means it has over heated i take it the pump is wired to the boiler pump over-run terminal On the pcb the reset and burner lights flash in different sequances denoting possible faults.
  8. G

    protherm 100e

    Sounds like it could be a blocked dhw heat/exch.
  9. G

    Glow worm Flexcom combi , any views?

    They have a problem with the ign. i.e very noisey .I will not be using them till it is sorted.The ali h/exch is used for cost purposes it is a cheap boiler and is cheaper to produce ali h/ech by the 1000 out of a foundry mould than pay to have a fabricated s/s ones.
  10. G

    Ecotec F.75.

    Have been fitting a few of these recently and have a couple come up with the fault code. One was sticking pump the other was water pressure switch have been told by vaillant the pressure s/be at least 1.5bar
  11. G

    how to drain hot water only on Saunier Duval 30e

    You need to release the pressure out of your system as this boiler does not have a dran cock,there are two methods to achieve this with the boiler isolated release water out of the prv.The other method is with the boiler isolaters open, open a radiator drain off cock and release the pressure...
  12. G

    VUW 824e - diverter or diaphragm

    Also said it is 10 years old perhaps a bit of clarification needed before we can definetley diagnose.imho
  13. G

    how to drain hot water only on Saunier Duval 30e

    How else would you drain a boiler without a boiler drain cock then.Seems in the realms of d.i.yer without endangering the neighbourhood.
  14. G

    VUW 824e - diverter or diaphragm

    I agree about the aqua sensor gasguru but not on a 10 year old boiler i think they did not change till about year 2000 onwards possibly the wrong info being posted.
  15. G

    VUW 824e - diverter or diaphragm

    The diaphram is in the divertor on a 10 year old model best to replace the lot [divertor complete} they tend to leak. should take about 25 min when used to doing them, allow yourself an hour.I adjust the micro switch as well.
  16. G

    how to drain hot water only on Saunier Duval 30e

    isolate the flow and retun release the prv filter underneath the pump if it is a SD30E p.s prv will probably leak so another way is to put hose on system drain cock
  17. G

    Glowworm Micron Wont Fire Up....?

    First check the gas at the boiler is switched on. Check meter is on if token you have credit, if yes to these , callout corgi to check gas valve/lead etc. If the property is h/a then it is there responsibility to fix it
  18. G

    Glowworm Ultimate 50FF & pilot light

    Ignore previous post wrong boiler If it continues to spark after the pilot is established it could be a fault on the ign. lead not rectifying the fuse blowing could be due to ext. controls/pump the aps is made to start the sparking process and has 240v through it so coud blow a fuse if wiring...
  19. G

    Glowworm Ultimate 50FF & pilot light

    If the thermister blows as chris said it takes the board out,but you still have power/fault lights you will have to bite the bullet and get a corgi out as it seems very likely the gas valve is faulty, silly thought is the gas isolater on the previous engineer may have turned the gas off.
  20. G

    Glowworm Micron Wont Fire Up....?

    The micron 50 does not have a twin electrode the 70/80 does.The new pcb is supposed to be good, fitted one last month lasted one ignition before breaking down. The replacement has lasted so far.