  1. G

    micron pcb

    Two slow flashes indicate polarity wrong check its wired in correctly permanent, live switch live, neutral, and earth and check pump over-run is wired.Did you have orange lights before if so i dont know if that was phase sensitive.The new board there are two types pijnenburg or the new...
  2. G

    Vent cockup

    if you fit a vent no need for p,r,v but the vent must be 22mm as mentioned by chris you can tee off 15mm to tank but to the flow pipe 22mm
  3. G

    Hot Water Problem

    open the tap if you can push the pin back usually indicates diaphram has split in it
  4. G

    glowworm swift manual

    try phoning glow-worm they normally send literature out if requested as do most other manufacturers
  5. G

    icon23t spares

    try standard pump washers with a bit of lsx from memory the original are rubber and if over-tightened crunch up the spares should be available through glow-worm if you go down that route unfortunately the manual does not show spares or part numbers.
  6. G

    Vaillant ecopro max 28e

    boilers more than adequate for your needs apart from the facia its a glow-worm hxi so you may consider one of these as they are normally a couple of hundred cheaper.
  7. G

    Vent cockup

    The pump is normally donstream so it pulls the cold feed and not air from the vent it is in 22mm min as this deemed to not block as easy as 15mm pumping over is as bad as pulling air because the water movement is oxygenating the syst leading to a shorter life due to corrossion. the pipe can be...
  8. G

    boiler has leaked brown water and makes loud bang noise

    Sounds like an energy saver 40 E ticking could be electrode not lighting and explosive ignition could be electrode,electrode lead,gas valve letting bye.The water problem is probablly condesate leaking possibly new h/exc. the seals go or possible fan leaking or condeaste tube perished maybe...
  9. G

    Can I change my own boiler?

    Apparently not you must be corgi in your own right their rules not mine.Icant install my own boiler unless registered used to be able to provided i was competent and not doing it for financial gain.Asked the same question at last corgi inspection that was their reply.
  10. G

    Glow Worm Ultimate: Pilot light not igniting

    Sounds like the ignition lead is arcing out on casing. Have senn it many times replace lead or move it usually cures said problem.
  11. G

    What Combi do you recommend?

    Power flush in many cases a waste of time and money since B.G started this fad every one jumps on the band wagon if your syst. is that bad spend your hard earned on replacing the 20 or 30 year old rads. Could never see the logic in power flushing with a new boiler in situ.And correct me if wrong...
  12. G

    backboiler, dead... how do i get rid of it?

    Last time i turned fire off but left back boiler working corgi gave me a rollicking as they are deemed one appliance [must both be safely working] So would assume in your case the same applies.Stand corrected if wrong opnly going by corgi at time.
  13. G

    What Combi do you recommend?

    A.W.B dutch boiler owned by glow-worm been condensing before worcester they used alulminium h/exch . Glow-worm like many moved away from ali in favour of stainless if syst. ok no problem heat/exch diff. minimal, corrosive values extreme hence the change. In defence of worcester they line ali...
  14. G

    What Combi do you recommend?

    I have a glow-worm 38cxi been installed by me for 18months not one problem same stainless heat/exch. as vaillant grundfoss pump etc only difference paid 200 quid less worcester are ok as are ideal dont install potties so wont comment what ever you choose make sure its installed by a pro(not...
  15. G

    Jaguar combi boiler - sorry!!!!

    If yhe pressure still rises after you have disconnected filling loop it could be one of two things either exp. vess. failed or needs pumping up or could be blocked exp. tube. The lack of hot water could be faulty diaphram partially blocked secondary heat exch. or flow restrictor not installed...
  16. G

    Leaking Gloworm 24CI Combi

    It is part of the filling loop it sometimes drips when you repress. the syst there is probably muck in the seating. If it is continually leaking i norrmally replace them. p/no 2000802600
  17. G

    Icon 23t flue??????????

    just a thought as you wont skip it try glow-worm hermann make a crppy condesing version the flue should be compatible
  18. G

    Jaguar boiler losing pressure/replace expansion vessel?

    you can definetley take the expansion vessel oot without removing boiler from wall i have done it before
  19. G

    icon 23t rising pressure

    check pressure in new exp. vess had one the other week pumped up to 2.5 bar released pressure problem solved also bleed rads could have hydrogen in syst. due to previos problems
  20. G

    Jaguar boiler losing pressure/replace expansion vessel?

    If you have enough height you can remove the expansion vessel without taking the boiler from the wall