  1. W

    RWB9 Connection issues to Potterton Suprima HE

    Yes your right i must have worked too hard today, try moving the wire frm terminal 2 to terminal 1.
  2. W

    Moving a roomstat

    Some have a screw holding the cover on underneath the dial which just pulls off.
  3. W

    RWB9 Connection issues to Potterton Suprima HE

    Check the wiring diagram connections on the back of programmer, terminal 1 is "on" not "off", the switch connections shown on the back of programmer cross over look closely, i think 1 is hw on and 4 is hw off.
  4. W

    Overflowing cold water tank

    Mixer taps are supposed to be byflow (if they are legal) so no cross connection can happen, if it is a ilegal mixer cold water going back up hot pipe will come out of open vent but only when both taps are on and it won't know what time of day it is the op says only at night.
  5. W

    Overflowing cold water tank

    Yes i know what you mean Doitall your thinking split coil in cylinder but op is saying only since shower has been installed and there isn't a bath.
  6. W

    Overflowing cold water tank

    Triton electric shower would/should be connected to the mains supply not down services so it would be impossible unless you have a cross connection somewhere.
  7. W

    Non standard pipe

    Can't you buy a different one which has flexible pipe? there is a link to these on another post on here.
  8. W

    New stack pipe

    Then yes you will require a vent.
  9. W

    Fitting new toilet cistern.

    Don't know much about these valves, but i would think it is a pressure reducer.
  10. W

    New stack pipe

    If you mean you are going to renew underground drain and new soil stack then yes you will need to vent above highest window approx 1 metre. The vent pipe is required to stop the flush from the toilet causing self syphonage which will remove water seal in wc pan and let in foul smells from sewer.
  11. W

    Overflowing cold water tank

    What type of electric shower have you got?. When you say water is back filling into cold tank do you mean up the cold feed to the cylinder or up the open vent pipe?. If you mean up the cold feed to the cylinder, this would not be possible if your plumbing is correct because you should not...
  12. W

    Potterton Lynx II boiler discharg CH water through waste pip

    By opening the pressure relief valve you have got some sludge holding the valve off it's seating, you need to turn it on and off with a snap action a few times this will usually reseat it, the repressurise.
  13. W

    Long drain, double stub stack

    If you have manholes on the main drain at the junctions of stub stacks, you won't need rodding eyes as you will be able to rod back to stub stacks. You can install clearing eyes on stub stacks as well.
  14. W

    Vallant Boiler

    Most likely blocked heat exchanger, pressure vessel might need repressurising and i would renew pressure relief valve.
  15. W

    New Siphon (or alternative) for close-coupled 3 bolt fixing

    Why do you have to keep patching it up?. Can you post pic's?. Have you removed cistern from pan, is there one large nut bolting the syphon unit through the cistern?.
  16. W

    Long drain, double stub stack

    Yes but you should check with local public dept. Use durgo valves on stub stacks make sure you have manholes at both junctions of stub stacks for rodding access.
  17. W

    motorised valve

    If motorised valve gets siezed it will hold in micro switch which will stop it from turning off.
  18. W

    Rushing water sound when C/H starts

    Water rushing sounds in pipework usually means air. Do you mean all flow & returns are 15mm or do you mean gas supply is 15mm?.
  19. W

    Worcester Bosch 24i RSF - Heat Exchanger Replacement

    You will need a RGI for this job.
  20. W

    Heating off but one hot radiator?!

    Bathroom rad probably used as a bypass.