Search results

  1. S

    Baxi combi 80 eco problem

    This would have shown if as I said by putting the manometer in the inlet pressure nipple. As the gas valve opens you would have seen the gauge drop to nothing. Lets not dwell on the past, the main thing is you have sorted it
  2. S

    ideal isar intemitent dhw fault

    The description your are giving is confusing. You say it doesn't come on when you open the tap then it does?? Had a friend had a problem with one of these. Would constantly showing in hw water mode ie: showing "d". Turned out to be a leaking tap. He confirmed this by isolating the cold feed to...
  3. S

    Baxi combi 80 eco problem

    Agree with above post. Is the gas valve working? are you getting voltage to gas valve? if you have you manometer on inlet nipple , do you see a drop when the gas valve should be opening? Have they got gas? Have you accidentally pulled out ignition lead from board/spark generator? Has boiler...
  4. S

    central heating problem

    As Dave said earlier. try pressing the overide button to get the green light on. You did mention that the boiler has a timer, make sure that the time is selected or it is on continuous. If the green light is on and it still doesn't come on then it could be the reciever unit itself. A way to...
  5. S

    BAXI 551/552 BACK BOILER CUTTING OUT ?

    The say the motorised valve has been change? Did they change the complete valve or just the head? Some people tend to try changing the head first only to find it's the valve that is sticking or passing.
  6. S

    FLAVEL REGANT GAS FIRE

    If you have at least one of the radiants. you will find a number engraved on the back. This should be enough info for the partscenter. It was when I needed one last year. Unforetunately I cannot remember any other info. Good luck
  7. S

    worcester greenstar 28i junior tripping out

    Is it the 28i Junior condensing boiler? At the bottom of the panel, (below and to the left) of the reset botton is there a blue light? If it has locked out, the blue light will be flashing. In the back of the instructions it will have a chart to give an indication of the fault by identifying if...
  8. S

    Glow Worm Ultimate 40FF Boiler

    You can run the fan without. If you are that worried then you can ring glowworn and they will send you a replacement. I have done this and there was no charge.
  9. S

    Still struggling with WorcesterBosch240RSF

    Are we maybe going in a bit deep? Have you tried reseting the overheat stat?
Back