  1. F

    Honeywell 8EP407N

    Thanks for advise Eighty, what you describe makes sense now.. maybe see how we go and always put the second pad up on fleabay. you're correct purchased already as seemed a reasonable system for price.. never thought of alarm before but seems the crims are on the increase around my area so want...
  2. F

    Honeywell 8EP407N

    Any advise for first alarm install, Im not in the trade but wanted to secure my house. Comfortable with my ability (famous last words), but wanted to ask on some possible do/donts. Kit includes 3 pet tollerant PIRS, 2 door contacts, GEN 4 control and 2 RKP's + as per earlier post (...
  3. F

    Honeywell Reason8 LED

    Purchased a honeywell 8ep407n pet kit with additional dummy reason8 bell box to match.. company sold me a battery operated flashing led to go in dummy. after checking contents tried dummy led in box but cant even see it in darkness through blue lense. Then read on line that the green and red...
  4. F

    baxi 105e luke warm water when taps on full flow

    Final update for time being . great thread by Puddle... dismantled diverter, cleaned , greased and voila,, piping hot water with taps on full.. Only comment is to add is care to be taken when removing actuator bush as fair amount of water comes out even after draining.. Also as precaution cover...
  5. F

    NEW INSTALL.. Any comments welcome..

    Many Thanks, for comments PIRS, door contacts included ,, so should be a nice little project..
  6. F

    NEW INSTALL.. Any comments welcome..

    Looking to install new alarm. Can anyone advise on quality of the following kit, HONEYWELL 8EP407N with additional RKP and dummy bell box, maybe dialer later on.. Link - http://www.e-fireandsecurity.co.uk/ade-honeywell-8ep407n-uk-g4-pet-tolerant-intruder-alarm-kit-8ep407n/p2167 Mainly...
  7. F

    Manrose timed fan 3A SFCU

    So first option should be more beneficial as SFCU can be turned off to replace Fan without affecting light in dark and dingy closet.....
  8. F

    baxi 105e luke warm water when taps on full flow

    i see your point ,, however after further investigation have now found that CH flow pipe gets hot on DHW demand.. so isolated CH flow/return and turned tap on full ,, surprise surprise piping hot water.. now found a thread on here from Puddle around stuck diverter and how to dismantle clean...
  9. F

    baxi 105e luke warm water when taps on full flow

    Old post I know ,,, but did any of the sufferers manage to cure the problem of luke warm water.. I would be interested to see if the offered remedies cured the issue. :roll:
  10. F

    Manrose timed fan 3A SFCU

    Thanks all, will decide at weekend to go whole hog or direct from ceiling rose. Decisions decisions...... :shock:
  11. F

    Manrose timed fan 3A SFCU

    And I quote from the included paperwork "The fan MUST be connected to a double pole fused spur having a contact separation of at least 3mm in all poles. It must be used and fitted with a 3 amp fuse, and should be sited outside any room containing a shower etc etc ..." so in answer its not...
  12. F

    Manrose timed fan 3A SFCU

    OK,, so read lots of posts with varying in depth explanations. For reasons required i have blocked window up in downstairs cloakroom so want to fit a timed fan.. Small issue, instructions require 3 amp fused for live and switched live. I am planning to wire in as per sketch as it seems to be the...
  13. Untitled

    Untitled

  14. wiring

    wiring

  15. F

    baxi 105he fan warning light

    i had a similar issue last year.. mr Boiler man came round and it ended up being a tiny cobweb in the venturi.. He cleaned it out and hey presto.
  16. F

    Baxi 105e sticky pin on CH differential valve

    MR CRS is there an online outlet for the service kit as local plumb merchants want to sell me a new 3 way..
  17. F

    Baxi 105e sticky pin on CH differential valve

    DP I don't follow ur comment
  18. F

    Baxi 105e sticky pin on CH differential valve

    Pin on CH differential valve (Top) is sticking. On demand pin raises and all is well. However when demand stops pin does not retract enough to disengage the micro switch causing an error 60. Pin can be eased down manually which removes error and all fires up. Question ? Does this sound like the...
  19. F

    Baxi 105e 60 error

    Final Update I hope... Now checked boiler again to diagnose issue myself. Heard a small click and then saw 60 error go out after a while.. Found that Pin on top of diverter valve was not returning to resting position correctly when DHW was turned off., in turn not releasing micro switch. Need...
  20. F

    Baxi 105e 60 error

    micro switch replaced by engineer and fine for 2 days but now back as usual