    Running a current through garage door handle?

    Well in addition to the rabbit food and the car, your garage needs to contain a Doberman.
  2. J

    installing fridge and cooker

    you forgot electric wok :?
  3. J

    Lintel replacement

    If it's a cavity lintel then it is not going to be done for £400. You will need to support ceiling joists (if they rest on the wall above the lintel) and also the blockwork of the inner skin. You will need 2 acrows and 2 strongboys for every 800mm of opening width (one outside every 800 and...
  4. J

    fluorescent light removal

    Beautifully said Dingbat!! Lorn, your original post looked like it was written by an underachieving 10 year old! It's twice as difficult to understand as a correctly punctuated one. As has been said, why should anyone here spend time helping you if you can't even be bothered to explain...
  5. J

    eathed metal conduit or capping

    Also you shouldn't cut such a deep chase in a wall less than 300mm thick (as a single skin - cavity wall doesn't count here) as Building Regs require horizontal chases to be less than one sixth the thickness of the wall. I know diagonal is not quite horizontal (!) but you can see where I'm...
  6. J

    eathed metal conduit or capping

    Yep, that's true. But in reality what's more likely (and safer). I'd go the earthed conduit method every time. :)
  7. J

    Flat Roof, Concrete Floor....

    Keep the cable within 150mm of the ceiling and you are within the rules, then drop vertically to the switch.
  8. J

    eathed metal conduit or capping

    You can't use plastic in this situation. Regs state "must be enclosed in earthed metal conduit, trunking or ducting........." Regulation 522-06-06 :)
  9. J

    eathed metal conduit or capping

    Can't agree Breezer, regs state conduit, trunking or ducting, which must be earthed. Capping is none of these.