Search results

  1. G

    Standard accessories used with DC

    Have you tried.... http://www.gepowercontrols.com/eu/product_portfolio/residential/minature_circuit_breaker/mcb_ep100uc.html Gareth
  2. G

    12 volt ride in Toy Car potentiometer

    What about an Electronic Speed Controller ? http://cgi.ebay.co.uk/36V-30A-DC-Motor-Speed-PWM-Electronics-Controller-/290550737238?pt=UK_BOI_Electrical_Components_Supplies_ET&hash=item43a62c6956 You could have a "dash board" mounted potentiometer wired in series with the foot switch.
  3. G

    Reposition plug socket for new cooker hood/extractor

    It might be abit tight, but would this work ? You also wouldn't have to extend the cables, but the circuit would still have to be RCD protected.
  4. Untitled

    Untitled

  5. G

    Sockets switch tripping although no sockets switched on.

    Try unplugging everything, rather than just switching off, it could be a faulty appliance. Dont forget about any sockets that may me hidden, eg. fridge, dishwasher or boiler ect.
  6. G

    Yes, circles, squares, straight and dotted lines ! It takes a while, but I think that the end...

    Yes, circles, squares, straight and dotted lines ! It takes a while, but I think that the end result is worth it. Email sent is the address you gave me.
  7. G

    Yes no probs, give me your email and I'll send them to you. I made them in MS Publisher and...

    Yes no probs, give me your email and I'll send them to you. I made them in MS Publisher and saved them in acrobat format. There is a total of about 10 of them.
  8. G

    spot the mistake?

    Sorry, schoolboy error ! Third time lucky
  9. Untitled

    Untitled

  10. G

    spot the mistake?

    OK then, try...
  11. Untitled

    Untitled

  12. G

    spot the mistake?

    What about:
  13. Untitled

    Untitled

  14. 1

    1

  15. G

    PME earthing system and RCDs

    webde; I think that you need to understand exactly what an RCD does. An RCD 'senses' an imbalance between the live and neutral wires. If 10 amps goes down the live , then 10 amps comes back through the neutral. If there is a difference of 0.03 amps (30 ma), ie you touching the live or...
  16. G

    rcbo query

    Yes a crimp will be just fine, use a red one and fold the bare copper from the white lead to about three time its original thickness to get a good surface area to crimp.
  17. G

    Earthing System & Tranny

    Phasing ??
  18. G

    Socket Heights and Switch Positions From Corner

    Its 450mm to the bottom and 1200mm to the top of the accessory. I don't believe that there is a set distance from the door frame.
Back