Search results

  1. G

    thermostatic mixer shower problem

    Is it plumbed in correctly?
  2. G

    worcester 28cdi

    How do you normally turn of the heating?
  3. G

    Fitting A Mira Electric Shower

    The whole unit has to be replaced, so the plumbing and electrical connections will have to be remade. As has already been mentioned, you will need to check the electrical loading.
  4. G

    Oil burner fails to start intermittently

    If the reset button on the burner is not lit up, then it has not gone to lockout, so pushing it should make no difference. So lets assume that it is lighting up. This being the case, the generic causes will be no oil / ignition / flame proving. Definitley worth cleaning the photocell and...
  5. G

    balancing radiators

    No - the idea of balancing the system is to ensure that the heat is distributed evenly around all the rads - which, from your post, is now the case.
  6. G

    Oil burner fails to start intermittently

    When you say that you push the burner reset button, is it actually lit up?
  7. G

    Low Loss Header

    Thanks Onetap
  8. G

    Flow and return fro different places?

    You don't say what type of system you have installed. The fact that you have M/V's would suggest that you have a water cylinder? If so, the return from the cylinder must be the last tee on the return to prevent reverse circulation. The new rad that you installed with a M/V on the flow, have...
  9. G

    Central Heating won't turn off......

    Select hot water only, heating off, when hot water switches off do you hear valve motor across, does boiler switch off? If so, try same with heating valve, you should then be able to identify which valve is faulty. You can also do the checks with a multimeter.
  10. G

    Rogue CH System

    OV microbore systems can be a real pain to get the air out of.
  11. G

    shower door clips

    Might be easier to contact the manufacturers spares dept.
  12. G

    Vaillant Ecotec pro pump failure

    If I remember correctly, Vaillant use Grundfos pumps so it is usually possible to just change the head.
  13. G

    Oil boiler filled with soot

    I think you will find there is more to it than just the air damper. If it is that sooted, then the burner and baffles will need to be removed to give the CC a good clean. Also the oil pressure will need checking, smoke #, amongst other things. Might be best to get an engineer in.
  14. G

    Low Loss Header

    Sorry to drag up such an old thread These links no longer seem to be valid, does anybody know which books they related to / have new links? Thanks
  15. G

    polystyrene beads and electrical cable twin and earth

    Ive pulled a fair number of tails from cavities with the polystyrene ball insulation but none of them have had the reaction that t&e does - why is that?
  16. G

    Suitable cable to carry 240V 250mtrs??

    Cant you park your caravan closer to the barn? You must have / going to have power to the barn
  17. G

    Kitchen ring mains, cable routing

    Points 1-5 & 7 as 1st fix, inspector will need to see these as well as explain point 9 Point 10 2nd fix You will need more than an ohmmeter to carry out the necessary testing. Are you aware of the tests you need to carry out? Will building control accept your test results - thought...
  18. G

    ABB S191 C10 mcb single phase

    Have you tried www.thefusecompany.com
  19. G

    consumer unit trouble

    Theres so much glaringly wrong with that board it has to be a joke right Kind of thing you expect to see on 2391 - look at this board and record any faults that you can see