  1. JPC

    Cold Radiator - possible blocked pipe?????

    have u closed down the other rads to see if it will then flow throu this rad?
  2. JPC

    Bath tap problems - noise

    hi...u need to have the panel off (or able to see inside) and turn the water back on ...to spot where its leaking from...then u know what to fix
  3. JPC

    Bath tap problems - noise

    might it be a leak under the bath ?
  4. JPC

    Problem with Vertical radiator only heating some elements

    bit of an old post ?...some rads have baffles to aid flow and direction of flow has to be observed
  5. JPC

    MIRA EXCEL not working (from new)

    sorry will be more helpfull. electric showers should be mains fed (cold) not via a combi. as to whats wrong with it after that, dunno
  6. JPC

    No hot water!! - HELP!!!

    assuming u dont have a combi...put the hot water (at the boiler/programmer)on and see if the pipe going into the tank get hot (pipe halfway down the cylinder) and comes out cooler (inline with the other but below it by about 12 inches)
  7. JPC

    air in system

    just so she can keep getting you round to bleed them :wink:
  8. JPC

    pipework in solid floor

    plastic in conduit is fine..no joints etc always good under floor !!
  9. JPC

    Leaking underfloor rad pipes

    a leak does not normally lead to air in a rad. is it open vented central heating system or sealed (combi boiler?)
  10. JPC

    Combi boiler & shower problem

    yes...call the plumbing company back...the shower should now be fed from the combi...not the tank...both hot and cold from the mains/combi so u don't get different pressure problems re ur shower
  11. JPC

    hot water too hot

    he has a tank...might not be a combi 8) is the tank stat set aroun 60 ? does the valve close the water off to the dhw when it should ? turn the heatin only on and see if the hot water travels to the cylinder also
  12. JPC

    New cistern leaking at flushpipe

    does it leak on the underside then ? needs tightning up with some large pump plyers...not over done but more than hand tight. is the cistern "body" aroun the opening smooth so the rubber makes a good seal ?
  13. JPC

    Is Magnaclean the best?

    i use to fit the magnacleans, but have moved over to tf1 due to better design..ie drain point (good/better for adding chemicals)
  14. JPC

    Valve Change Clarification

    yes could help
  15. JPC

    Half a Radiator

    could be slight blockage to one of the rad valves....just open the trv and the other side fully open ...see if that helps...open and close them a few times... still nothing...close the other rads down by closing the trv...see if that warms ur problem rad
  16. JPC

    Angle of the Dangle

    u can/need have a slight incline..minimum about 1 inch a meter...if this does not meet ur outlet from the wall u have to put a 135 or 90 fitting on it
  17. JPC

    adding a pump to gravity hot water system

    a bit more involved than that...go to manufactures website and have a look...some have some good diagrams
  18. JPC

    Fitting A New Gas Hob

    i think powell is right....try local plumbers from gasafe or yellow pages.....but best bet would be a recomendation from someone
  19. JPC

    moving hot water storage tank

    its the distance from the cws to the outlet (s) so placing the hwsc in the loft wont have any effect on performance...u will have to place the cws higher than the hwsc...obviously