  1. Qedelec

    Hi Rob, thanks for your interest but it aint broke, I just never got round to developing it...

    Hi Rob, thanks for your interest but it aint broke, I just never got round to developing it. Paid for the domain on a whim, but as I had enough work coming in it seemed stupid to advertise. Maybe I will have to advertise if this slump, thats predicted, happens.
  2. Qedelec

    Consumer Unit Relocation Project

    :oops: I must have been asleep! didn't think of swa. Did you mean 87mS. My tester don't measure .1mS
  3. Qedelec

    Immersion Heater Timer Question

    Fit two timers.
  4. Qedelec

    Consumer Unit - 17th edition compliance

    er.. if this is a Starbreaker you will need a replacement bus bar, and crabtree RCD's take 3 slots. I have not seen the new Crabtree boards so cannot see how they will get over the bus bar problem. Another route for you might be to convert the board to a Wylex. Both are made by Electrium in...
  5. Qedelec

    New Kitchen Old problem.

    Are you really a spark?? Probably not or you would know the answer. From your post I assume you are having a gas hob and the supply is for ignition only. So the answer is yes.
  6. Qedelec

    Bathroom light

    Don't put the earth in the switch!!! Put red in 'blank' = com and black (sleeved in brown) in L1.
  7. Qedelec

    Consumer Unit Relocation Project

    The RCD time, is that 8.7 milliseconds? And the circuit labelled Vaults, is the Phase and CPC conductore both 6mm?
  8. Qedelec

    Supply voltage

    That reminds me of a call out I had when I worked in computers. It was to the site office of a well known road builder near Nottingham. The fault that was reported was the printer kept stopping. Could not make the fault happen on my visit and just to be thorough I checked the supply, you guessed...
  9. Qedelec

    Fixing a strip light batten: joist distances

    Have this problem a lot although not always strip lights. Easiest solution is plaster board fixings. Not much weight so two fixings plus one at the centre where the cable enters.
  10. Qedelec

    terminations

    Rule of thumb is to get as much copper in the terminal as possible. Double all single conductors up to 2.5mm.
  11. Qedelec

    Not a good idea to use grey twin + earth for outside electrics. it is not designed to be exposed...

    Not a good idea to use grey twin + earth for outside electrics. it is not designed to be exposed to the elements. As far as the regs are concerned it only says a cable must be protected against damage, which leaves it open to interpretation. Good practice is for a supply to be in SWA (Steel...
  12. Qedelec

    photos of quality workmanship and more

    'runny clips'are caused by the pvc in the cable reacting with the plastic in the cleat. This should not happen with modern materials.
  13. Qedelec

    12 Volt Lighting - Where to put Transformers

    Its a better idea to have one tx per light. Then you can right them in the ceiling with access via the fitting hole.
  14. Qedelec

    12v downlighter comes on for a second, then goes out . . .

    They'll be cheaper from an electrical wholesaler. Shed's add 100% for the elevator musac :lol:
  15. Qedelec

    one ring main?

    Its quite common. Tests you can do: 1. Continuity of each conductor, Line, Neutral and CPC 2. Insulation tests between Line & CPC, Line & Neutral and Neutral & CPC 3. Connect in comming Line to outgoing CPC and vice versa, then measure between Line and CPC (R1 + R2) at each each socket...
  16. Qedelec

    12v downlighter comes on for a second, then goes out . . .

    They are electronic 'transformers' and are the likely cause. not expensive to replace. You can thank whoever installed them that they used one TX per light or they would all have gone out and would be more expensive to replace (approx 3 x price)
  17. Qedelec

    Retailers selling 17th Edition red book

    Got mine from amazon, free delivery and it arrived in a couple of days (better than Parcel Farce). Oh and only £61.75
  18. Qedelec

    Power in the garden

    Terminate the cable with an exterior SWA gland and mount the gland in an adaptable box.
  19. Qedelec

    Sockets operated by light switches

    Not insane at all. You need to ensure that the sockets can only be used for the lighting, so I suggest 5a round pin plugs. And yes they are still available.
  20. Qedelec

    lighting

    2 cables or 3 cables, which is it?