Search results

  1. Qedelec

    wat is the best way to start out on your own

    Oh Adam you are a tease!!
  2. Qedelec

    wat is the best way to start out on your own

    What about N-E fault??
  3. Qedelec

    Fuse Box - Can i add to it ?

    If your not concerned with safety, yes he could. In my experience they dont have the staff/knowledge to know the difference between a cable and a rice pudding.
  4. Qedelec

    Can you get a double socket, but one half hardwired?

    Double 1 gang back boxes and pattresses are available.
  5. Qedelec

    Shower Room conversion (extractor fan)

    If there is no access to the lighting circuit, then using a SFCU to supply a fan and light is permissable. Add a three pole isolator for the fan.
  6. Qedelec

    newboy with some questions.

    Why not speak to one of the competent persons schemes, they will be better placed to advise what they require to register you for self certification. You could take one of those 3day courses like most kitchen fitters :roll:
  7. Qedelec

    Electric certificate

    Not really Matt, in my experience LABC would not have sufficient knowledge to say if the readings presented to them were whithin those laid down by BS7671. Your spark would want to know that any work he does which relies on the safety of the existing installation is not compromised by shortcuts...
  8. Qedelec

    Supplementary Bonding (Electric shock from bath taps)

    Equipotential and supplementary bonding is all about making sure all exposed metalwork is joined together electrically thus all is at the same potential, hence equipotential. The danger would come from an appliance fault causing the exposed metal to become live, then there is likely to be a...
  9. Qedelec

    Fuse Box - Can i add to it ?

    And that constitutes adding an additional circuit, for which you need an Electrical Installation Certificate.
  10. Qedelec

    Electric certificate

    The Electrician that carried out the work is the only one who would have a copy. The number given to you by the builder is likely to be the submission number for notification of LABC under Part P of the building regulations. I am not sure if that is much use to you. Did you not receive a...
  11. Qedelec

    Fuse Box - Can i add to it ?

    Adding a new cicuit requires an Electical Installation Certificate signed by a 'compentent' person. That is competent in the legal sense.
  12. Qedelec

    Replacing a photocell

    Without knowing the make/model, who can say. Have you considered having a separate Photcell (PIR), then you can take advantage of the miriad of outdoor lights available
  13. Qedelec

    Triton Spellbind shower tripping RCD

    CB, regarding drawing in a new cable, a few tips. Whenever possible, pull the cable up, not down, debris has a habit of dropping down and jamming the cable. Strip enough insulation off both cables to allow you to bend back at least an inch, preferably 2. Wrap tape around the join, making sure...
  14. Qedelec

    Wiring for bathroom refit

    I very much doubt that you are an imbicile, and I am sure in your own field you have to conform to the rule book. As for the size of cable you will need for this work, you will need to calculate it based upon the load, route, length of run. There is more to it that just picking from a chart. I...
  15. Qedelec

    Wiring for bathroom refit

    While I understand your desire to save money, there is a huge difference between houses and boats apart from the obvious. For example holes in joists weaken the structure. Expecting an electrician to sign off your work is illegal and would you risk your livelyhood on someone you didnt know?
  16. Qedelec

    Shock!!!

    Blimey! Don't tell me you can 'feel' 30mA. you could be useful for fault finding :lol:
  17. Qedelec

    Lighting circuit not earthed

    He's already got a neutral, he needs a cpc. I am surprised that the installer failed to include an earth, only houses without a cpc that I have seen were wired in the 60's. You may be lucky and could find the cables will pull the new ones in. remember to only pull cables up to prevent debris...
  18. Qedelec

    Supplementary Bonding (yes, I can hear you all groaning!)

    17th edition came in on jan 1st.
  19. Qedelec

    Demand in Scotland for Electrical Testing

    Test instruments?
Back