  1. C

    Moving a loo

    Why can't you just make a new hole to the outside in your new position and alter soil pipe to suit?. This would be a much better option than what you are suggesting.
  2. C

    condensing boiler drain question

    Hi forget the pipe which is a safety discharge pipe and nothing will be coming out of it except in a fault condition, you should be lookig at getting the flue extended to where it won't condense on the underside of the walkway or see if the manufacturers do a plume kit for your boiler.
  3. C

    Converting close coupled to combined feed & vent

    The first picture you have posted shows a conventional H system layout nothing wrong at all with it, except maybe the horizontal section is a bit high above the pump. I wouldn't change this layout apart from maybe lowering the horizontal section, what is the distance above horizontal section to...
  4. C

    Boiler parts required

    Hi Tony no this boiler isn't a baxi, it is a boiler a friend of mine asked about as he was trying to source a part, I've NOT SEEN IT MYSELF.
  5. C

    Boiler parts required

    H i does anyone know where to source parts for a Solaire combi boiler?. Wall hung fan assisted open flue boiler about 12years old, the part I require is the flow switch.
  6. C

    Glowworm 30cxi condensate leak

    Are you sure it's not coming from condensate trap the early boilers had a problem with blue cap on the bottom splitting?.
  7. C

    glowworm micron 50ff start stop prob.querie

    Hi the replacement pcb for this boiler has a micro controller which is pre-programmed rather than a lot of relays which were fitted to the old board. I would suggest that the board is faulty.
  8. C

    changing heating pipes under floor

    Hi with your radiators coming off of manifolds, if you then tee off as you described you will get problems with balancing, change manifolds to ones you can take all yourr radiators from.
  9. C

    Possible Thermostat issue

    Hi if your heating comes on in the morning shouldn't think it would be your roomstat that wouldn't know what time of day it is, sounds more like timer settings put it on 24hr/constant see what happens.
  10. C

    potterton combi 80 boiler fault

    Faulty pressure vessel check FAQ7.
  11. C

    replacing tap

    Probably just the tap body has got water where it shouldn't have it you can turn mains water off won't affect your combi. Get a tap body replacement.
  12. C

    Combi boiler advice

    Hi by venting rad you have depressurised system see FAQ6.
  13. C

    Ventpipe in F&E Tank is constantaly running.....

    Seco i'm saying this because i have seen this problem and ifxed it by either resiting pump or cold feed 100's of times especially when i was doing pub work back in the 80's lovely jobs free beer with everyone.
  14. C

    Valiant Combi boiler

    Agile i think you will find that the AAV on this model is at the top right hand side.
  15. C

    Ventpipe in F&E Tank is constantaly running.....

    Question is the water in the F&E brown? if yes you will most likely have problems in the future with radiators starting to leak because they rust from inside. I would suggest that this system is pumping over more to do with wrong siting of the cold feed pipe and any blockages/sludge are not...
  16. C

    Worcester cut out

    Look in FAQ'S Num 7
  17. C

    glowworm 24cxi

    F1 fault is ignition failure, gas problem boiler tries to light then locks out. Have you run out of gas?.
  18. C

    Alpha 240P boiler

    You really need a rgi to do this job but if you insist on doing it yourself and seeing as you have already entered the section of the boiler where you shouldn't have. He's read it, and we don't want to encourage others for the reasons you stated, so I've removed your "dangerous" advice. Mod10
  19. C

    Alpha 240P boiler

    Do you mean you blew both tubes coming from aps?. That isn't going to clean the venturi.
  20. C

    Combi Boiler Won't Repressurise

    The built in filling loop on that range of boiler pretty u/s, I always fit an external filling loop.