  1. C

    Potterton Netaheat Electronic 16/22 - Nothing happening

    Have You got/checked motorised valves?, if the pcb fuse is okay and you say that the fan has been renewed (don't remove cover to check fan)as this boiler is a positive pressure type and can kill. The first part of the lighting squence is the fan and these are reliable, my guess is that it's...
  2. C

    Vaillant VCW GB242 water comming out of air bleeder

    Turn off flow and return isolating valves under boiler just above turnoff point on both valves there is a nipple loosen either one and catch the water this will empty boiler renew auto air vent.
  3. C

    Potterton Netaheat Electronic 16/22 - Nothing happening

    If you are confident about checking mains voltages and have the equipment check both sides of pcb fuse, you should check any other external controls 1st ie motorised valves.
  4. C

    Potterton boiler

    When frost stat operates in cold weather the flow will only being going around bypass as twgas suggests so if this is blocked or restricted, or not as spec the boiler will overheat and button will pop out.
  5. C

    Potterton boiler

    Only guessing on Model, but good point I believe MI stated 3metres 22mm pipe run for bypass on these, maybe system getting a bit blocked.
  6. C

    source of metal chippings in central heating system?

    Have a proper power flush done and fit a Magnaclean to system.
  7. C

    ideal classic boiler

    Your boiler is probably okay, you need to check external controls ie pump,m/valve etc.
  8. C

    Potterton boiler

    You don't say what model it is but it sounds like the button your talking about is the overheat reset on a Profile, the frost stat has nothing to do with this, it's an overide of the electrics to fire boiler to stop it freezing when everything is turned off. If the o/heat is popping out it...
  9. C

    How to reset a Micron Boiler

    Turn power to boiler off and on again this will reset it but you might have a problem which has caused it to need resetting.
  10. C

    Remeha Boilers

    Hi we have installed approx 20 of these boilers so far and have found them to be an easy boiler to fit, as already said quite small in size. We have found that all of them appear to lose pressure with no signs of any leaks anywhere in the systems or the boilers themselves, we have been in...
  11. C

    Viessmann Vitodens 100

    Hi all Can anyone help with any information regarding non return flap in fan of vitoden 100 i have been on to Tech and they said check this flap, i'm not familar with this make of boiler and there doesn't seem to be any information in Mi
  12. C

    Ferroli Modena 80 combi boiler problem

    You most likely need to replace your pressure release valve and check out faq 7.
  13. C

    getting a cistern pipe to stay connected to the pan?

    Sounds like your flush pipe has been cut to short this causes it to pull back.
  14. C

    Combi Boiler pressures and leaking overflow pipes

    Can you post pic's of airing cupboard/ red cylinders etc.
  15. C

    Combi Boiler pressures and leaking overflow pipes

    You haven't got a combi boiler. Check faq's for re-pressure expansion vessel.
  16. C

    50 gallons

    You can buy what is called a coffin tank which is that capacity, long and narrow, but i'm not sure if it would fit through your opening.
  17. C

    MATURE ACS STUDENT NEEDING HELP

    I don't think Agile has a fair point, i would rather help someone who has gone to the trouble and expense to take his ACS even if he did set up in competion with me, than be under cut by a cowboy unregistered so called fitter. If you know what your doing have fair prices do a good job you will...
  18. C

    F2 fault on Glow Worm 24ci

    Afraid your going to need a RGI you can't do this one yourself.
  19. C

    MATURE ACS STUDENT NEEDING HELP

    Seems a pointless reply to me Agile.
  20. C

    Best practice in location of isolation valves

    The cold feed is also the expansion pipe and should never have any sort of valve fitted to it mainly because a valve could be turned off and forgot leaving nowhere for the water to expand apart from open vent that is.