  1. S

    slow starting Compressor

    The other possibility, does the pressure relief valve work? when it get's up to pressure and cuts out, you should hear a hiss as the air between the pump and tank is released, this is so that when the pump starts again it doesn't start under full load, when it starts again the first half turn or...
  2. S

    pricing

    also prefer the time/hourly rate method, sometimes depends on the layout of the house too
  3. S

    periodic inspection?

    depends what they want, visual if that's what they ask for, but normally inspect & test with possible limitations agreed beforehand, do you have insurance & 2391?
  4. S

    Banging noise from Expansion vessel

    but it's not been doing it for the last year and a half
  5. S

    Banging noise from Expansion vessel

    it's just doin it as the tap is either opened or closed, not while the tap is running
  6. S

    Banging noise from Expansion vessel

    any idea why there should be a sort of cracking sound from an expension vessel on an unvented cylinder? makes the noise as the hot taps are tuned on & off
  7. S

    worcester 28i junior pressure rise

    If it's a pin hole or crack in the heat exchanger, the condensate will probably run more than normal when the heating is on
  8. S

    2 stroke petrol engine starts & dies

    they can do that when the piston rings are worn, I have a chainsaw that does it, but it is about 16 years old!!
  9. S

    RCD OVERLOAD

    It's TNS, they've sawn the stubs off the bus bar where the neutrals were, then brought a neutral down from the neutral bar to feed in from below, someone had put a lot of thought into getting it wrong, in fact, thinking even further, the output should be at the bottom, so they wouldn't even work...
  10. S

    RCD OVERLOAD

    main bond size should be 10mm if neutral meter tail is 25mm, potentially 100amp demand, because we're not supposed to examine the main fuse to ascertain it's size, we have to assume that it's not 60amp therefore a 63amp isolator is not up to the job, RCCB's are definately not RCBO's, old LN5780...
  11. S

    worcester 28i junior pressure rise

    would think either filling loop letting by or have known this on a potterton with a pin hole in the heat exchanger, condensate was running a lot on that though
  12. S

    RCD OVERLOAD

    Was called to a job the other day, MK sentry board (RCCB takes up 4 ways), shower switch had burnt contacts from loose connection as normal, noticed at the board that there were a lot of RCCB's and not many breakers, had a closer look, 2 ring mains, 1 cooker circuit and 1 shower circuit, all...
  13. S

    Old style MK Sentry CU cover required

    I think you'll be struggling with that one, got a 6 way (6 usable) with isolator and LN5780 RCCB, and a 3 way with RCCB as main switch if they're any use
  14. S

    House Survey Recommendations

    sounds about right, I was asked recently for a price on a rewire, punter was going to use quotes to knock down selling price, I went to see, did visual insp', suggested new CU, Upgrade of main bond etc, as I said to buyer and seller, if anyone dissagrees with my findings, get a 2nd opinion...
  15. S

    Unusal Shower Problem, NO RCD, Trips MCB, Rented House.

    seem to remember from talking to a property legal eagle, that if they don't have the electrics checked and something happens, they can get in trouble because they have not taken "all reasonable precautions", if there are things you can see by a visual inspection, ie, not dismantling, I would...
  16. S

    breathable paint for stone walls?

    cheers for that, looked at a wiring job the other day, someone said, "we're on a very tight budget" I noticed the tins of Farrow & Ball or whatever it's called and asked "if you're on a tight budget, how come you're usin that stuff" continued with the job and charged them my normal price...
  17. S

    breathable paint for stone walls?

    Cheers for that I was told similar by a spotty faced young kid in a decorators merchants, wasn't quite sure whether I should trust his advice but looks like he may have been right :lol:
  18. S

    breathable paint for stone walls?

    What is the best paint to use on plaster in a stone cottage, been told it needs to be able to breathe to help prevent damp getting locked into the wall
  19. S

    help-quick ring circuit question answered urgently plse

    as mentioned, why not sort it properly?, no mention of testing and certification etc
  20. S

    Small print

    also recently added after discussion with my solicitor, "if you are comissioning us to work for a limited company, please be aware that you are being viewed as guarantor for the contract, if the limited company goes into receivership or ceases trading for any reason, any accounts owing will be...