  1. O

    Galaxy 60 Advice

    check to see if the zone (circuit) is programmed correctly go into view zones, and have a look at the status of the circuit, when door is open/closed Oasis
  2. O

    tamper lock out

    try linking out T and A on the SAB connections, this might fix it, if it does, remove the tamper (global) and try to reset system, if this works, go buy a new bell box! hope this helps Oasis
  3. O

    CCTV 1V P-P

    when i worked for another large company based in Bradford, we used all of DM DVR`s and we had a batch of about 100 that did exactly what you have posted up. system freezes you have to then disconnect the power and then reconnect and the system works fine? if this is so, then the unit has...
  4. O

    bell box extra piezo mod

    NO wire the new piezo with the existing piezo connections, as they are a passive device not an active one! if you wire it as you say you will cook it! Oasis
  5. O

    THE NIGHT SHIFT

    as with Alarm as an alarm engineer my sleep patterns vary so much. i can be in the office at 0500 in the morning or 2330 it depends what needs doing i am always in the office on a sunday, i catch up on paperwork that needs doing, and its handy as the phone don't ring, people don't ask daft...
  6. O

    Long range Wirless CCTV Microwave?

    there is a companu called melsecure, they do units that will transmit over longer distances short range 300m + for about £450.00 available from ADI Gardiners not used it myself, but the tech spec looks good call ADI local brnach and ask Oasis
  7. O

    Long range Wirless CCTV Microwave?

    try CCTVDIRECT google them, have a look around, they have soon good kit thre. should be something available to you Oasis
  8. O

    Pet sensors.

    dont use them, unreliable and quite honest useless
  9. O

    Concept Alarm not charging back up battery and general?'s

    Alarm sorry mate you is a bit wrong on that one! its a resistor, part of the charging circuit. OP check your charging load, to the battery to ensure is giving you the correct current. 14.5 vdc is a good voltage, but you must have a good charge current as well Oasis
  10. O

    Installation of a LD2 Domestic Fire Alarm System

    as long as you get the certificate of compliance from the sparks in relation to the electrical side you should be ok, but ask him if he can provide a certificate of compliance as to the installation of fire detection equipment? i very much doubt it, but as long as the council are ok and your...
  11. O

    Random Tottenham riots!

    Nige yes mate, it is still my `manor` even though i dont live there anymore, but still have family there, and Enfield, Edmonton. Oasis
  12. O

    Random Tottenham riots!

    MM Tottenham is part of Haringey you numpty. the council offices are in seven sisters road, muppet! and with the `riots` moving to enfield, that is only 3 miles away from Tottenham, but those area just a few idiots who want to join the band wagon. MM learn you london boroughs mate and...
  13. O

    To identify camera?

    and 24vac ones aunt daisy used to use lots of 24vac ones Oasis
  14. O

    3 Phase DB Pics

    and amercan! compleat with grounded and grounding connections!!! or as we know the neutral and earth! Oasis
  15. O

    Random Tottenham riots!

    was born and raised on Tottenham (just off of the seven sisters road, very close to Seven Sisters tube) so i know the manor well, still lived there in `85 look up Broadwater Farm and then look at what happened Saturday night, and make your own judgements. its not a bad area, just some...
  16. O

    Honywell Galaxy 2 Series - 2 lots of 2 beeps during night

    check the log, ascanything the panel has to reprt will be logged there Oasis
  17. O

    Street Lighting

    basic really; concentric in and out of cutout in base then, depends on age of pole, to control photocell (or time switch) and then either to base fitted control gear for discharge lamp or up the pole in double sheath singles (small version of meter tails to the head if you can do...
  18. O

    Hardwired Smoke Detectors

    Gatowl use BS5839, local authority and the fire service, we use BS5839 and EN54, but then we do mainly commercial/industrial/liesure industry. we have a few renatl properties that we look after but not many, to much hassel with `i dont want to pay` landlords!! Oasis
  19. O

    Advice needed to catch scumbags in underground carpark

    Alumni i fully agree mate, Maplin should stick with resistors and the such like, not trying to sell 2nd rate DIY garbage! Oasis
  20. O

    Hardwired Smoke Detectors

    under law rental properties HAVE to have a minimum fire detection system fitted. it my just require stand alone interlinked smoke detectors or it may require an all singing and dancing full system; we always fit as required by the local authority, if they have not requested it we will fit...