    well i sit corrected, as i am not standing!!! its a hell of a long time since i fitted an alarm that uses LED`s to indicate an alarm condition! and ahell of a long time since i have fitted C and K stuff as well (sorry Honeywell now). but the thought is still the same, dis off the internal...
  2. O

    internal speaker

    or you can do the following; get into engineer mode, remove main panel cover, (the white box with battery and cabling in it) remove the internal speaker (unplug it) fit a new external speaker and connect it tot he speaker terminal on the PCB easy as that really and its cheap as well...
  3. O

    battery replacement

    if you have changed the battery for a new one, and checked the power supply fuse (with a meter, not just by looking at it) and these are ok. reset your system, try to set/unset and see what happens we used to fit the 800/816 and never had a problem when changing battery. what does the...
  4. O

    battery replacement

    you might have a blown fuse on the charging side of your control panel check and replace if required Oasis
  5. O

    Honeywell Galaxy 512 standby battery replacement ...

    as above; enter into enginner mode remove cover screws on control panel (big greyish box) BE CAREFULL OF MAINS VOLTAGE remove battery fit new battery (7AH 12V) replace cover and screws enter your user code, yes in engineer mode, press the `A` key then press the ESC key come out of...
  6. O

    CCTV BNC connectors?

    what we do is put up an IP65 plastic (usually 4 x 4) box outside and use that for sticking the cable from the camera and the extention cable going to your DVR. yes you can get extension cables, try Ebay Oasis dont cut the cable on the camera!! as its a bit of a pin to re connect!!
  7. O

    Scantronic Alarm

    PM me or call and i will gicve you some information Oasis
  8. O

    give me a call and i then can give you the info you need, Oasistechnical. (john harrison) on...

    give me a call and i then can give you the info you need, Oasistechnical. (john harrison) on 07954 146323, we are in London in the morning if you need any assistance
  9. O

    Wiring a PA to a Honeywell Galaxy 3-144c

    why do you want to connect it direct to the external siren?? just connect the HUD (PA Button) to the end sstaion then program the system parameters for that zone as PA Audible. all done! (ensure that you have one with fitted resistors, or one that has them built in as well) it means...
  10. O

    Yale Alarm Premium

    is it the final exit/entry door that you are leaving open? if so, thats ok (as long as it sets correctley) but there are a few on here that fit Yale as a matter of fact, so i think someone else will also post here to help you. Oasis
  11. O

    Sterling 10 battery changed but still sounding

    your system is now back to normal. keep a note of the date that you changed your battery and change it in about 4 to 5 years. nice to see what we do actaully is utilised by people!!! Oasis
  12. O

    Sterling 10 battery changed but still sounding

    it could be either of these; 1.6 amp 20mm 1.0 amp 20mm rather unsure as we dont fit that panel (and have only ever taken them out to replace with something else!) Oasis
  13. O

    Honeywell Galaxy 2-20 user reset rquired error

    sorry to hee this but you are going to have to contact a firm that can do this repair for you. unless you think that you could tackle it yourself? make sure the firms you contact can work on Galaxy panels, as not all firms can (or want to) Oasis
  14. O

    Sterling 10 battery changed but still sounding

    battery fuse ok? if you can use a multimeter, check all fuses in the end station and always be aware that there ismains in there! Oasis
  15. O

    Alarm ringing

    me personally would do a full reset of system including re programming. try that then look at the external siren/strobe unit, in some cases we have found that some external siren/strobe units have had this particular fault. Oasis
  16. O

    what type of fire alarm system is required?

    the first thing you need to get done is; a fire risk assesment!!!! BEFORE YOU DO ANYTHING!!!!! contact your local fire officer, they will be able to help you out also contact a fire alarm compeny that specicically does risk assesments then get threee quotes based on the FRA and the...
  17. O

    Honeywell detector wiring help

    zone connections com + EOL panel connections 1001+ middle connecton or 1002 + middle connection Z1 come Z2 dont eally make much sense on a GD96 to be honest!! Oasis a Honeywell Galaxy engineer!!! because thats all we fit!!!
  18. O

    alien pod

    its about a DVR mate! Horrible thing as well !! Oasis RTFM ?
  19. O

    We LOVE Pyro

    i have to agree with RF PYRO (or what ever you wanna call it) is great, cut my teeth on it many many years ago, love it, i would still prefer to wire a buildings fire alarm in pyro that most other cables!! in the days of the GLC all public houses and many other commercial buildings wer...
  20. O

    PM me mate and i will let you know the correct way to default G2 panel, (as the instructions...

    PM me mate and i will let you know the correct way to default G2 panel, (as the instructions given on my post were not made by me, they were done by one of my junior engineers) they will not work!!!